Gas Generator CG132B-16
Gas Generator Sets
Details
Continuous Rating
1000 ekW @1.0pf
Fuel Type
Natural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency
41.50%
Overview
700-1000kW Gas Generator
The Cat CG132B family of gas engines are perfectly tailored to the challenges of the power plant in an age of global value chains.
Benefits
hydrogen blended fuel option
Enables operation of up to 25% hydrogen blend (by volume) with pipeline natural gas fuel.
Digital Plant Control
Total Plant and Energy Management System (TPEM) gives you comprehensive and flexible digital control of your generator set�s efficiency and performance helping to reduce planning and installation costs.
Robust
Improved oil management with optimized cylinder and turbo chargers set new standards in terms of durability and reliability.
Features at a Glance
- Lower Operating Costs
-
- Optimized engine components mean the CG132 uses up to 50% less lubricating oil than competing generator sets, which means more money stays in your company's pockets
- Smaller footprint
-
- The CG132 uses nearly 50% less space than similar system
- Less space means lower installation costs
- Cat Total Electronic Management System
-
- Temperature and pressure monitoring for each cylinder
- Anti-knock control allow for maximum power output and the best possible fuel utilization, even if gas composition changes
- Flexible Fuel Usage
-
- Our gas-mixer technology and Total Electronic Management System let you use a wide variety of gases, including problematic gases like digester, landfill and sewage gases
Specifications
Full Specifications
- Generator Set Specifications
-
Continuous Rating
1000 ekW @1.0pfFuel Type
Natural Gas, Hydrogen Blend (up to 25%)Maximum Electrical Efficiency
41.50%Frequency
50 HzRPM
1500 rpmNatural Gas Rating
1000
- Engine Specifications
-
Engine Model
CG132BDisplacement
2135.8 in³Aspiration
TABore
5.2 inStroke
6.3 in
- Generator Set Dimensions
-
Length
165 inWidth
70 inHeight
85 inDry Weight - Genset
17791 lb
Equipment
- Standard Equipment
-
Air Inlet
- One-element single-stage air cleaner with enclosure and sevice indicator
- Turbocharger with a water-cooled bearing case for all cylinder
Control Panels
- TPEM (Total Plant & Energy Management System)
Cooling
- Flange connections for JW inlet and outlet
- Electrical jacket water and aftercooler coolant pump
- Jacket water and SCAC thermostats
- flange connections for JW inlet and outlet
- Cat flanges on SCAC circuit
- ANSI/DN customer flange connections for JW inlet and outlet
Exhaust
- Exhaust waste gate for the CG132B-16
- Closed crankcase ventilation system
- PEARL/Low resistence exhaust system
Fuel system
- Pre-chamber spark plugs
- Independently controlled cylinder monitoring and ignition system
- Electronic fuel metering valve
Generator
- Anti-condensation space heater
- Reactive droop
- 3-phase sensing and KVAR/PF control
- Busbar connections
- grid code generator
- closed-coupled generator result in no torque transmission to the base frame
- Reactive droop
- Winding temperature detectors
Starting/Charging
- 24V starting motors
- Battery disconnect switch
General
- Crankshaft vibration damper and guard
- Optional Equipment
-
Air Inlet
- Air cleaner with precleaner
- Mounting stand
Cooling
- CHP skid
Grid Code Compliance
- 50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands