G3520H Gas Generator

Gas Generator Sets

Details

Continuous Rating
2519 / 2500 ekW @ 1.0pf

Fuel Type
Natural Gas, Hydrogen Blend (up to 25%)

Maximum Electrical Efficiency
45.30%

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

1763 - 2519 kW Gas Generator

From natural gas to biogas, coal mine gases, or hydrogen fuel blends to support combined heat and power (CHP), emergency power, and local grid support applications, Caterpillar has a wide range of reliable gas power solutions.

Benefits

hydrogen blended fuel option

Enables operation of up to 25% hydrogen blend (by volume) with pipeline natural gas fuel.

savings on service

Extended maintenance intervals leading to lower service costs

Lower lube oil consumption

Leading to lower service costs and extended maintenance intervals

Features at a Glance

Cat G3520H Gas Engine
  • Robust high speed block design provides prolonged life and lower owning operationg costs
  • Designed for maximum performance on low pressure pipeline natural gas and hydrogen mixtures
  • Simple open chamber combustion system for reliability and fuel flexibility
  • Leading edge technology in ignition system and air/fuel ratio control for lower emission and engine efficiency
  • One electronic control module handles all engine functions: ignition, governing, air/fuel ratio control and engine protection
SR5 Generator
  • Designed to match performance and output characteristics of Caterpillar gas engines
  • Industry leading mechanical and electrical design
  • High efficiency
EMCP 4.3 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Emissions
        
  • Meets most worldwide emissions requirements down to 0.5 g/bhp-hr Nox level without aftertreatment
Proven System
  • Field proven in a wide range of applications worldwide
  • Fully prototype tested
  • Certified torsional vibration analysis available
Full Range of Attachments
  • Wide range of bolt-on system expansion attachments
  • Factory designed and tested
  • Flexible packaging options for easy and cost effective installation
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Full Specifications

Generator Set Specifications

Continuous Rating
2519 / 2500 ekW @ 1.0pf

Fuel Type
Natural Gas, Hydrogen Blend (up to 25%)

Maximum Electrical Efficiency
45.30%

Frequency
50 / 60 Hz

RPM
1500

Frequency
50/60 Hz

Engine Specifications

Engine Model
G3520H

Displacement
5956 in³

Aspiration
TA

Bore
6.7 in

Stroke
8.5 in

Compression Ratio
12.1

Generator Set Dimensions

Length
302 in

Width
86 in

Height
97 in

Dry Weight - Genset
54675 lb

Equipment

Standard Equipment

Control Panel

  • EMCP 4.3

Air Inlet

  • Two-element single-stage air cleaner with enclosure and service indicator

Cooling

  • Engine driven water pumps for jacket water and aftercooler
  • Jacket water and SCAC thermostats
  • ANSI/DN customer flange connections for JW inlet and outlet

Circuit Breaker

  • LSI Long-Time, Short-Time, Instantaneous Annunciator
  • Rear-mounted
  • 5000A 3-Pole IEC Rated Circuit Breakers

Exhaust

  • Center section cooled turbocharger with Cat flanged outlet
  • Dry exhaust manifolds, insulated and shielded
  • Individual exhaust port and turbocharger outlet wired to Integrated Tmeperature Sensing Module (ITSM) with GECM providing alarms and shutdowns

Fuel System

  • Electronic fuel metering valve
  • Throttle plate, 24V DC actuator, controlled by GECM

Fuel system

  • Fuel system is sized for 31.5 to 47.2 MJ/NM3 dry pipeline natural gas with pressure of 10.2 to 34.5KPa to the engine fuel control valve

Ignition System

  • Electronic Ignition System (controlled by ADEM A4)
  • Individual Cylinder Detonation Sensitive Timing (DST)

Generator

  • Caterpillar's Digital Voltage Regulator (CDVR) with 3-phase sensing and KVAR/PF control
  • SR4B
  • Crankshaft Vibration Damper and Guard
  • Busbar connections
  • Paint- Caterpillar Yellow except rails gloss black
  • Winding temperature detectors
  • Operation and maintenance manuals
  • Parts book
  • Anti-condensation space heater
  • RH Service
  • SR5
  • Reactive droop

Govrerning System

  • ADEM A4 4-20mA (0-5VV) Speed Input
Optional Equipment

Air Inlet

  • Mounting Brackets and Piping
  • Air cleaner with precleaner

Circuit Breaker

  • MP- Frame 6 Pole Bottom Cable Entry
  • 4000/5000A Neutral Current Transformer Automatic Selection
  • No UV trip or package mounted CB Wiring
  • Frame Mounting

Control Panel

  • 16 Point/32 Light Annunciator, Shipped Loose
  • Remote Communications Module (PL1000T, PL1000E)
  • Remote annuciator
  • Local PC Monitorring
  • Discrete I/O Module, 12 Digital Inputs, 8 'Form C' Relay
  • Cat Connect: Ehternet, Satellite, Cell Telematics
  • Engine failure relay
  • Local alarm module
  • Synchronizing module
  • Remote PC Monitorring

Cooling

  • Inlet/Outlet connections
  • Coolant level drain line with valves, fan with guard

Exhaust

  • Muffler and spark-arresting muffler with companion flanges
  • Flange
  • Elbow
  • Flexible Fitting
  • Exhaust Expander

Fuel System

  • Gas Knockdown Regulator
  • Fuel filter
  • Gas pressure regulator
  • Gas shutoff valve 24V, ETR (Energized-To-Run)

Generator

  • Bearing temperature detectors
  • Cable access box
  • Low voltage extension box
  • Manual voltage control
  • European bus bar
  • Generator air filter
  • Medium and high voltage generators and attachment

General

  • Digital diagnostic tool
  • Special paint order
  • Tool set
  • US AID Emblem

Starting/Charging

  • Battery with cables and rack (shipped loose)
  • 24V starting motors
  • Jacket water heater
  • 60A, 24V charging alternator (requires engine driven pumps)

Grid Code Compliance

  • 60 Hz: USA
  • 50 Hz: Germany, Great Britain, Belgium, Romania, Italy, Ireland, Poland, Netherlands, Spain, France, and European Standard

Similar New Power Solutions

G3512 1000kW Gas Generator Set
Gas Generator Sets

G3512 1000kW Gas Generator Set

Gas Standby Rating: 1000 ekW @ 0.8pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 5%)
Emissions/Fuel Strategy: U.S. EPA Certified for Non-Emergency Stationary Genset

G3512 750kW Gas Generator Set
Gas Generator Sets

G3512 750kW Gas Generator Set

Gas Standby Rating: 750 ekW @ 0.8pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 5%)
Emissions/Fuel Strategy: U.S. EPA Certified for Non-Emergency Stationary Genset

Gas Generator G3512H
Gas Generator Sets

Gas Generator G3512H

Continuous Rating: 1515 ekW / 1505 ekW @1.0pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency: 44.90%

Cat G3520H Combined Heat and Power (CHP) Solution
Gas Generator Sets

Cat G3520H Combined Heat and Power (CHP) Solution

Continuous Rating: 2480 ekW @ 1.0pf
Fuel Type: Natural Gas
Maximum Electrical Efficiency: 42.40%

Cat G3516H Combined Heat and Power (CHP) Solution
Gas Generator Sets

Cat G3516H Combined Heat and Power (CHP) Solution

Continuous Rating: 1982 ekW @ 1.0pf
Fuel Type: Natural Gas
Maximum Electrical Efficiency: 42.90%

Cat G3512H Combined Heat and Power (CHP) Solution
Gas Generator Sets

Cat G3512H Combined Heat and Power (CHP) Solution

Continuous Rating: 1490 ekW @ 1.0pf
Fuel Type: Natural Gas
Maximum Electrical Efficiency: 42.50%

DG500 (3-Phase)
Gas Generator Sets

DG500 (3-Phase)

Frequency: 60 Hz
Natural Gas Rating: 500 ekW
Emissions/Fuel Strategy: U.S. EPA Certified for Stationary Emergency and Non-Emergency Application

DG100 (60 Hz)
Gas Generator Sets

DG100 (60 Hz)

Frequency: 60 Hz
Gas Standby Rating: 100 ekW
Emissions/Fuel Strategy: U.S. EPA Certified for Stationary Emergency Application

DG125 (Single-phase and 3 phase) (60 Hz)
Gas Generator Sets

DG125 (Single-phase and 3 phase) (60 Hz)

Frequency: 60 Hz
Gas Standby Rating: 125 ekW
Emissions/Fuel Strategy: U.S. EPA Certified for Stationary Emergency and Non-Emergency Application

DG150 (3 phase) (60 Hz)
Gas Generator Sets

DG150 (3 phase) (60 Hz)

Frequency: 60 Hz
Natural Gas Rating: 150 ekW
Emissions/Fuel Strategy: U.S. EPA Certified for Stationary Emergency and Non-Emergency Application