DG400 (3-Phase)

Gas Generator Sets

Details

Frequency
60 Hz

Natural Gas Rating
400 ekW

Emissions/Fuel Strategy
U.S. EPA Certified for Stationary Emergency Application and Non-Emergency Applications

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

More output in a compact package

The Cat® DG400 gas generator set delivers 400 ekW for standby, demand response and limited-time power applications. Its lean-burn CG18 engine combines fuel efficiency with durable construction for steady operation over the long term.

Benefits

Use installation space more effectively

Lower your owning and operating costs

Adapt controls to your operation

Features at a Glance

High power density
The in-line six-engine CG18 delivers greater output from a smaller engine configuration, allowing more power to fit within a smaller space.
Efficient CG18 engine
Lean-burn operation promotes fuel efficiency, while robust high-speed block construction contributes to prolonged engine life.
Flexible Cat® ECS controls
Expansion modules and customizable programming configure generator operation around individual installation needs.
Strong motor-starting ability
Large connected motors can start during an outage, helping accommodate demanding electrical equipment.
Durable alternator insulation
Class H insulation provides a high level of protection to promote alternator durability over its service life.

Specifications

Full Specifications

Generator Set Specifications

Frequency
60 Hz

Emissions/Fuel Strategy
U.S. EPA Certified for Stationary Emergency Application and Non-Emergency Applications

RPM
1800

Voltage
208 - 600 VAC

Natural Gas Rating
400 ekW

Fuel Type
Natural Gas

Engine Specifications

Engine Model
Cat® CG18 In-line 6, 4-cycle Natural Gas

Fuel System
Gas mixer, Venturi

Aspiration
Turbocharged - Air-to-Air Aftercooled

Governor Type
Electronic

Displacement
1106.3 in³

Compression Ratio
10.5:1

Bore
5.7 in

Stroke
7.2 in

Generator Set Dimensions

Length
154 in

Width
73 in

Height
82 in

Weight
10721 lb

Equipment

Standard Equipment

Exhaust

  • Dry exhaust manifolds, insulated and shielded

Fuel System

  • Gas train with Zero Pressure regulator
  • ECU controlled shutdown solenoid
  • Airfuel Ratio Control, Venturi type Air-Gas mixer, throttle controlled valve

Controls

  • CAT® ECS 100
  • Integrated Voltage Regulator (IVR)

Telematics

  • PL444 Product link 4G LTE Telematics

Generator

  • Anti-condensation space heater
  • SR5

Governing

  • Electronic Governing

Starting/Charging

  • 24V starting motors

General

  • Paint - Caterpillar Yellow except rails are gloss black
  • Operation and maintenance manuals
  • Parts book
Optional Equipment

Air Inlet

  • Air inlet adapters

CONTROL PANEL

  • CAT® ECS 200

Cooling

  • Inlet/Outlet connections

Exhaust

  • Flexible fitting
  • Elbow, Flange
  • Muffler and spark-arresting muffler with companion flanges
  • Exhaust expander

Generator

  • Permanent Mangnet Excitation
  • Low voltage extension box
  • Cable access box

Enclocures

  • Sound Attenuated and Weather Protective

Starting/Charging

  • Jacket water heater
  • Space Heaters
  • Charging alternator
  • Battery with cable and rack (shipped loose)
  • Battery charger
  • Oversized battery

General

  • Engine barring group

Similar New Power Solutions

G3520H Gas Generator
Gas Generator Sets

G3520H Gas Generator

Continuous Rating: 2519 / 2500 ekW @ 1.0pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency: 45.30%

G3512 1000kW Gas Generator Set
Gas Generator Sets

G3512 1000kW Gas Generator Set

Gas Standby Rating: 1000 ekW @ 0.8pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 5%)
Emissions/Fuel Strategy: U.S. EPA Certified for Non-Emergency Stationary Genset

750 kW Natural Gas Generator Sets:G3512 With Fast Response
Gas Generator Sets

750 kW Natural Gas Generator Sets:G3512 With Fast Response

Gas Standby Rating: 750 ekW @ 0.8pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 5%)
Emissions/Fuel Strategy: U.S. EPA Certified for Non-Emergency Stationary Genset

Gas Generator G3512H
Gas Generator Sets

Gas Generator G3512H

Continuous Rating: 1515 ekW / 1505 ekW @1.0pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency: 44.90%

DG500 (3-Phase)
Gas Generator Sets

DG500 (3-Phase)

Frequency: 60 Hz
Natural Gas Rating: 500 ekW
Emissions/Fuel Strategy: U.S. EPA Certified for Stationary Emergency and Non-Emergency Application

DG100 (60 Hz)
Gas Generator Sets

DG100 (60 Hz)

Frequency: 60 Hz
Gas Standby Rating: 100 ekW
Emissions/Fuel Strategy: U.S. EPA Certified for Stationary Emergency Application

DG125 (Single-phase and 3 phase) (60 Hz)
Gas Generator Sets

DG125 (Single-phase and 3 phase) (60 Hz)

Frequency: 60 Hz
Gas Standby Rating: 125 ekW
Emissions/Fuel Strategy: U.S. EPA Certified for Stationary Emergency and Non-Emergency Application

DG150 (3 phase) (60 Hz)
Gas Generator Sets

DG150 (3 phase) (60 Hz)

Frequency: 60 Hz
Natural Gas Rating: 150 ekW
Emissions/Fuel Strategy: U.S. EPA Certified for Stationary Emergency and Non-Emergency Application

G3520 2000kW Gas Generator Set
Gas Generator Sets

G3520 2000kW Gas Generator Set

Gas Standby Rating: 2000 ekW @ 0.8pf
Fuel Type: Natural Gas, Hydrogen Blend (up to 5%)
Emissions/Fuel Strategy: U.S. EPA Stationary Non-Emergency Certified

CG260-16 Gas Generator Set
Gas Generator Sets

CG260-16 Gas Generator Set

Continuous Rating: 4300 / 4000 ekW @1.0pf
Fuel Type: Natural Gas, Biogas, Coal Gas, Associated Gas, Synthesis Gas, Hydrogen Blend (to 25%)
Maximum Electrical Efficiency: 44.1 / 43.8%