DE660 GC (50 Hz) Generator Set
Diesel Generator Sets
Details
Standby Rating
660 kVA
Frequency
50 Hz
Emissions/Fuel Strategy
Low BSFC
Overview
660 kVA Diesel Generator Set
Producing reliable power 660 kVA at 50 Hz, our DE660 GC generator set powerd by C15 diesel engine designed to ISO 8528-5 transient response requirements.
Benefits
Control System
- Track Genset Health and Operation Parameters
- Genset Utilization and Performance Tracking
Monitoring
Cat Connect option ensures your generator set is always ready to start and perform as expected
Lower Fuel Consumption
Longer run times between fuel fills; reduced operating costs
Features at a Glance
- Cat Generator Set Package
-
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
- Cat Diesel Engine
-
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
- A-Frame Alternator
-
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
- GCCP 1.1 Control Panel
-
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
- Cooling System
-
- Designed to operate in standard ambient temperatures up to 55°C (131°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
- One Safe Source
-
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
- Worldwide Product Support
-
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Specifications
Full Specifications
- Generator Set Specifications
-
Standby Rating
660 kVAFrequency
50 HzEmissions/Fuel Strategy
Low BSFCVoltage
380 to 415 VoltsSpeed
1500 rpmDuty Cycle
Standby
- Engine Specifications
-
Engine Model
C15 In-line 6, 4-cycle dieselBore
5.4 inStroke
6.8 inDisplacement
928 in³Compression Ratio
16.1:1Aspiration
Turbocharged Air-to-Air AftercooledFuel System
EUIGovernor Type
Adem™A4
- Generator Set Dimensions
-
Length - Maximum
131 inWidth - Maximum
60.6 inHeight - Maximum
86.1 inDry Weight - Genset (maximum)
8364 lb
Equipment
- Standard Equipment
-
Engine
- Cat® C15 Inline 6 cylinder, 4 stroke diesel
Air Inlet
- Air cleaner
Control Panels
- GCCP 1.1
Governor
- Mechanical governor
Cooling
- Package mounted radiator
Alternator
- A Frame standard alternator
Fuel Storage
- Single wall 8 hour fuel tank
Cooling System
- Radiator and cooling fan with guards
- Fan drive, battery charging alternator drive
Fuel
- Fuel priming pump
- Primary fuel filter with integral water separator
- Secondary fuel filters
Electrical Options
- 3 Pole Circuit breaker
- Neutral earth link
- 24 Volt battery with rack and cables
Air inlet system
- Air cleaner; light duty with disposable element
Generator
- Matched to the performance and output characteristics of Cat engines
- Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
- IP23 Protection
Lube system
- Lubricating oil
- Oil drain line with valve
Mounting system
- Captive linear vibration isolators
- Lifting provision and drag points
General
- Engine and alternator pre paint, Caterpillar yellow
- Engine and alternator pre paint, Caterpillar yellow
Power Termination
- Busbar
Generator and Attachments
- Power center, IP22
- Segregated low voltage (AC/DC) wiring panel
- Optional LC Frame generator - IP23 Protection
- Integrated voltage regulator (IVR)
- Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
Mounting
- Rubber vibration isolators
Governing System
- Cat electronic governor (ADEM A4).
Lube System
- Oil cooler
- Oil drain valves
Mounting System
- Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines
- Optional Equipment
-
Control panel
- PLG 4G/3G/Ethernet
- Annunciator
- Emergency E-Stop
Exhaust
- Industrial, residential, critical mufflers
Enclosure
- Cat GC enclosure
Generator
- Oversize and premium generators
- Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
- Anti-condensation heater
Electrical Options
- 4 Pole Circuit breaker
- Auxiliary contacts
- Padlockable circuit breaker
- Battery charger
- Wet battery
Power Termination
- Circuit breakers, UL listed
- Circuit breakers, IEC compliant
Alternator
- Space heater
- AVR
Generator and Attachments
- Oversize A Frame generator
- LC frame generator
- LC frame CIP generator
- Ingress protection
- CIP A Frame generator
- Permanent magnet excitation (PMG) generator
- Oversize LC frame generator
- Space heaters
Starting/Charging
- Oversize batteries
- Charging alternator
- Jacket water heater
- Battery chargers
- Heavy duty starting system
- 24 Volt battery with rack and cables
Air inlet system
- Single stage air filter
- Dual element air filter
Certifications
- EU Certificate of Conformance (CE)
- EAC Certification
General
- The following options are based on regional and product configuration:
- Sound attenuated, weather protective or high ambient weather protective enclosure
- UL 2200 package
- CSA Certification
- Narrow, wide or skid base
- EEC Declaration of Conformity
- EU Certificate of Conformance (CE)
- Single or dual wall sub-base fuel tanks
- Single or dual wall integral fuel tanks
- Automatic transfer switches (ATS)
- Integral & sub-base UL listed dual wall fuel tanks
- Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
Extended service coverage
- 3, 4, 5 and 10 Years
Enclosures
- High ambient sound attenuated enclosures
- Sound attenuated enclosures
Exhaust System
- Industrial silencer
- 10 dBA Attenuation silencer
- 6 and 8 inch elbow kit
- Flexible exhaust fittings
- 6 and 8 inch flange GP
- Manifold and turbocharger guards
- End in/end out mufflers - 10, 25 and 35 dBA attenuation
- Engine mounted muffler
Fuel System
- Optional BS799 Compliant Integral Dual wall 8 hour fuel tank
- Single wall 8 hour fuel tank with spill containment
- Low fuel level shutdown
- Low and high fuel level alarms
- Manual fuel transfer pump
- Optional BS799 Compliant Integral Dual wall fuel tank base
- Fuel transfer system controls
Lube System
- Manual sump pump
Mounting System
- Narrow skid base - replaces standard fuel tank base
Special Test / Reports
- PGS Test report @ 1.0 power factor
- PGS Test report @ 0.8 power factor
Starting / Charging System
- 5 Amp single Battery charger
- Jacket water heater
- Battery disconnect switch