C7.1 ACERT

Diesel Generator Sets

Details

Maximum Rating
220 kVA

Minimum Rating
135 kVA

Emissions/Fuel Strategy
Non Regulated, EU Stage IIIA

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

135 - 220 kVA Diesel Generator Set

Producing reliable power from 135 to 220 kVA at 50 Hz, our C7.1 diesel generator sets designed to ISO 8528-5 transient response requirements. All C7.1 generator sets are available with a choice of emissions levels.

Benefits

& Testing environments

Lower Fuel Consumption

Longer run times between fuel fills; reduced operating costs

Hours

Ensures you can count on emergency power when it is needed

Features at a Glance

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
M-Frame Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP 1.3 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
  • Image may not be a representative of actual product
Cooling System
  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
Fully prototype tested with certified torsional vibration analysis available
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
World Wide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Full Specifications

Generator Set Specifications

Maximum Rating
220 kVA

Minimum Rating
135 kVA

Emissions/Fuel Strategy
Non Regulated, EU Stage IIIA

Voltage
110 to 480 Volts

Frequency
50 Hz

Speed
1500 rpm

Duty Cycle
Standby, Prime

Engine Specifications

Engine Model
Cat® C7.1

Bore
4.1 in

Stroke
5.3 in

Displacement
427.8 in³

Compression Ratio
16.0:1, 18.2:1

Aspiration
Turbocharged, Air to Air Aftercooled

Fuel System
Direct Injection

Governor Type
Mechanical

Generator Set Dimensions

Length - Maximum
98.4 in

Width - Maximum
52 in

Height - Maximum
64 in

Equipment

Standard Equipment

Air Inlet System

  • Air cleaner; light duty with disposable element

Control Panels

  • EMCP 4.1

Cooling System

  • Radiator and cooling fan with guards
  • Fan drive, battery charging alternator drive
  • Coolant drain line with valves
  • Caterpillar extended life coolant

Fuel System

  • Base, formed steel with single wall integral 8-hour fuel tank
  • Standard open set fuel tank/base supplied

Exhaust System

  • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose

Generator and Generator Attachments

  • Segregated low voltage (AC/DC) wiring panel
  • Voltage regulator (single phase sensing)
  • Tower panel, IP22, bottom cable entry
  • 12 Leads

Governing System

  • Mechanical and electrical governing system - model dependent

Lube System

  • Oil drain line with valve
  • Lubricating oil

Generators and Generator Attachments

  • IP23 Protection
  • Circuit breaker, IEC, 3 pole, mounted in tower panel

Mounting System

  • Includes lifting provision and drag points
  • Captive linear vibration isolators between base and engine-generator
  • Captive linear vibration isolators between base and engine-generator
  • Termination points for coolant and lube oil drain lines

Starting / Charging System

  • 24V battery with rack and cables

General

  • Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment

Alternator System

  • 3 Phase sensing
  • Optional LC Frame alternator
  • Optional LC Frame alternator with coastal insulation protection
  • R Frame auxiliary winding: R2273L4 SE aux alt 07, aux alt 08 and aux alt 10
  • Permanent magnet excitation (PMG)
  • Quatrature droop king
  • Alternator removal
  • Anti-condensation heater

Circuit breakers

  • 4 Pole 250A, 400A and 630A Circuit breakers
  • Padlockable breaker device

Control System

  • 1000001235
  • Static battery charger
  • Control panel heater
  • Volt free contacts for common alarm
  • Volt free contacts for generator set running

Control Panel Options

  • Overload shutdown via breaker

Cooling System

  • Low coolant level shutdown
  • Coolant heater
  • Low coolant temperature

Enclosures

  • Rental options (CAE only) - Single point lift
  • Rental options (CAE only) - Rental pack
  • Rental options (CAE only) - CEE form sockets for enclosure
  • Sound attenuated level 2 enclosure
  • Sound attenuated level 1 enclosure
  • Rental options (CAE only) - Socket blanking plate

European Certifications

  • Upgrade to STD set for CE

Fuel Systems

  • Skidbase for CALG enclosure sets
  • Open set narrow tankbase
  • Low fuel level alarm
  • DEFRA bunded fuel tank
  • Low fuel level shutdown
  • High fuel level alarm
  • Compact skidbase for open sets

Global Certifications

  • Certification for CIS

Mounting Options

  • Electronic governor
  • Industrial silencer removal
  • Residential silencer
  • Battery removal
  • Silencer installation kit

Test Reports

  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8 power factor

General

  • Stone guards/radiator trans flange

Power Termination

  • Circuit breaker, IEC, 4 pole

Accessories / Miscellaneous

  • Packing case - compact set
  • Packing case - canopied set

Similar New Power Solutions

C1.1 Generator Set
Diesel Generator Sets

C1.1 Generator Set

Maximum Rating: 9.5 kVA
Minimum Rating: 6.8 kVA
Emissions/Fuel Strategy: R96/EUIIIa Equivalent

C1.5 Generator Set
Diesel Generator Sets

C1.5 Generator Set

Maximum Rating: 13.5 kVA
Minimum Rating: 10.0 kVA
Emissions/Fuel Strategy: R96/EUIIIa Equivalent

C3.3 Generator Set
Diesel Generator Sets

C3.3 Generator Set

Maximum Rating: 65.0 kVA
Minimum Rating: 24.0 kVA
Emissions/Fuel Strategy: EU Stage II R96/EUIIIa

C2.2 Generator Set
Diesel Generator Sets

C2.2 Generator Set

Maximum Rating: 22.0 kVA
Minimum Rating: 13.0 kVA
Emissions/Fuel Strategy: R96/EUIIIa Equivalent

C4.4 Generator Set
Diesel Generator Sets

C4.4 Generator Set

Maximum Rating: 110 kVA
Minimum Rating: 50 kVA
Emissions/Fuel Strategy: EU Stage II & R96/EUIIIa

3512B Diesel Generator Set
Diesel Generator Sets

3512B Diesel Generator Set

Standby Rating: 1625/1600/1500 kVA
Prime Power Rating: 1500/1360 kVA
Emissions/Fuel Strategy: Low Fuel , Low Emissions

3512 Generator Set
Diesel Generator Sets

3512 Generator Set

Standby Rating: 1400/1250 kVA
Prime Power Rating: 1275/1150 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516B Generator Set
Diesel Generator Sets

3516B Generator Set

Standby Rating: 2250 kVA
Prime Power Rating: 2000 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516 Diesel Generator Set
Diesel Generator Sets

3516 Diesel Generator Set

Standby Rating: 2000 kVA
Prime Power Rating: 1825 kVA
Emissions/Fuel Strategy: Low Fuel Consumption

C18 Generator Set
Diesel Generator Sets

C18 Generator Set

Maximum Rating: 500 ekW
Minimum Rating: 455 ekW
Emissions/Fuel Strategy: U.S. EPA Tier 4 Final