3516 Diesel Generator Set
Diesel Generator Sets
Details
Standby Rating
2000 kVA
Prime Power Rating
1825 kVA
Emissions/Fuel Strategy
Low Fuel Consumption
Overview
1600 - 2000 kVA Diesel Generator Set
Producing reliable power from 1600 to 2000 kVA at 50 Hz, our 3516 diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100% rated load in one step. Generator sets offer both low fuel consumption and low emission systems.
Benefits
Global Operating Hours
Proven performance in heavy-duty applications
Shipped
Since 1981, leading the large engine market
Lower Fuel Consumption
Demonstrated savings in operating costs
Features at a Glance
- Cat Generator Set Package
-
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
- Cat Diesel Engine
-
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
- SR5 Alternator
-
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
- EMCP 4 Control Panel
-
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
- Cooling System
-
- Designed to operate in standard ambient temperatures up to 50°C (122°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
- Certifications
-
- EU Declaration of Conformity
- EU Declaration of Incorporation
- Eurasian Conformity (EAC)
- Telecommunication Lab of China
- One Safe Source
-
- Components used in the generator set are selected at the design stage to provide optimum package performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
- World Wide Product Support
-
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Specifications
Full Specifications
- Generator Set Specifications
-
Standby Rating
2000 kVAPrime Power Rating
1825 kVAEmissions/Fuel Strategy
Low Fuel ConsumptionVoltage
380 to 415 VoltsFrequency
50 HzSpeed
1500 rpmDuty Cycle
Standby, Mission Critical, Prime, ContinuousMaximum Rating
2000 kVAMinimum Rating
1600 kVA
- Engine Specifications
-
Engine Model
3516 TA, V-16, 4-Stroke Water-Cooled DieselBore
6.69 inStroke
7.48 inDisplacement
4210.64 in³Compression Ratio
13.0:1Aspiration
TAFuel System
Mechanical unit injectionGovernor Type
Woodward
- Generator Set Dimensions
-
Length - Maximum
234.4 inWidth - Maximum
90 inHeight - Maximum
94.9 inDry Weight - Genset (maximum)
33840 lb
Equipment
- Standard Equipment
-
Air Inlet System
- Air cleaner; single element canister type
Governing System
- ADEM A3
Control System
- Auto/start/stop control
- EMCP 4.2B
- Environmental sealed front face
- Generator mounted - rear facing
- Speed adjust
- 24 Volt DC operation
- Generator set packages include Caterpillar's voltage regulator
- Text alarm/event descriptions
- Emergency stop pushbutton
- Engine cool-down timer
- Engine cycle crank
- IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter. Limiter and exciter diode monitor
- Controls:
- Alarm acknowledge
- Lamp test
- PLC functionality
- Load histogram feature
- 3 Analog inputs
- Operating hours
- Serial annunciator module data link
- Digital indication for:
- 4 programmable relay outputs (Form A)
- ATAAC - 3516E package radiators shipped installed
- Communications:
- Customer data link (Modbus RTU)
- Reverse reactive power (kVAr) (32RV)
- Accessory module data link
- Number of I/O varies on options selected
- RPM
- Overcurrent (50/51)
- Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
- 1 programmable relay outputs (Form C)
- 1 programmable digital outputs
- Cat connect
- 6 Customer programmable digital inputs
- Certified standard PGS provided
- Volts (L-L & L-N)
- Coolant temperature
- Oil pressure (psi, kPa or bar) - Coolant temperature - Volts (L-L & L-N) - Frequency (Hz) - Amps (per phase & average) - Power factor (per phase & average) - kW (per phase, average & percent) - kVA (per phase, average & percent) - kVAr (per phase, average & percent) - kW-hr (total) - kVAr-hr (total)
- Frequency (Hz)
- kVA (per phase, average & percent)
- Amps (per phase & average)
- Power factor (per phase & average)
- kVAr (per phase, average & percent)
- kW (per phase, average & percent)
- kW-hr (total)
- kVAr-hr (total)
- Failure to start (overcrank)
- Emergency stop
- Overspeed
- Warning/shutdown with common LED indication of shutdowns for:
- High coolant temperature
- Low oil pressure
- Programmable protective relaying functions
- Low coolant level
- Low coolant temperature
- Generator phase sequence
- Over/under frequency (81 o/u)
- Over/under voltage (27/59)
- Reverse power (kW) (32)
Exhaust System
- Dry exhaust manifold
- Flanged faced outlet(s)
Fuel System
- Fuel priming pump
- Flexible fuel lines - shipped loose
- Secondary fuel filters
- Fuel cooler; not included with packages without radiator
General
- Right hand servicing
- Flywheel and flywheel housing - SAE No. 00
- Caterpillar yellow with high gloss black rails and radiator
- SAE standard rotation
Generator and Attachments
- Winding temperature detectors
- Busbar connections, right side extension box, bottom cable entry
- Permanent magnet excitation (PMG)
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby
- Busbar connections, top center mounted, top cable entry
- Anti-condensation space heater
- NEMA standard hole pattern
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
- Low voltage:
- Winding temperature detectors
- Form wound
- Medium voltage:
- Winding temperature detectorsle pattern
- NEMA standard hole pattern
- Six lead
- Form wound
- Internal excitation (IE)
- 3 Phase brushless, Salient pole
- Random wound
- Busbar connections, top center mounted, top cable entry
- Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
- High voltage:
Literature
- Parts book
Lubrication System
- Oil drain lines and valve
- Lubricating oil
- Gear type lube oil pump
- Integral lube oil cool
- Fumes disposal
- Oil filter, filler and dipstick
Mounting System
- Rails - Engine/generator/radiator mounting
- Rubber anti-vibration mounts - shipped loose
- Anti-vibration mounts (shipped loose)
Starting System
- 24 Volt electric starting motor
- 45 Amp Charging alternator
- Battery disconnect switch
- Battery and battery rack w/cables
- Optional Equipment
-
Control System
- Local annunciator module: [ ] NFPA 110 [ ] Custom
- EMCP 4.3, EMCP 4.4
Air Inlet System
- Dual element air cleaner
- Single element filter
Cooling System
- Water level switch gauges
- Coolant
- Standard ambient radiators
- Standard ambient ATAAC radiators
- Optional installed ATAAC radiators
- Optional installed radiators
Engine Options
- Starting aids: [ ] 220V 50 Hz Jacket water heater
- Air cleaner: [ ] Single element air cleaners [ ] Dual element air cleaners [ ] Heavy duty air cleaners
- Batteries: [ ] Standard (1400 CCA) [ ] Heavy Duty (2800 CCA)
- Starting motors: [ ] Standard [ ] Heavy duty
- Muffler: [ ] Industrial Grade
Crankcase System
- Explosion relief valves
- Ventilation system
- No explosion relief valves
Alternators
- Temperature rise (over 40°C ambient): [ ] 150°C [ ] 125°C [ ] 105°C [ ] 80°C
Exhaust System
- Y Adapters
- Exhaust offset
- Tier 4 dosing cabinet
- Flexible fittings
- Elbows
- Clean emission parts
- Tier 4 clean emissions module
- Flanges
- Tier 4 clean emission MOD Kits
- Mufflers
- Flange and exhaust expanders
Fuel System
- Fuel priming pumps (Tier 4) - Manual or electric
- Primary fuel filter
General
- UL 2200 package
- US aid emblem
- Special paint (Colors other than Caterpillar yellow or high performance paints)
- Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
- The following options are based on regional and product configuration:
Power Termination
- Circuit breaker operation: [ ] Electrical
- Circuit breaker trip unit: [ ] LSI [ ] LSIG [ ] LSIG-P
- Power termination: [ ] Busbar [ ] Circuit breaker
- Circuit breaker rating: [ ] 2000A [ ] 2500A [ ] 3200A [ ] 4000A
Generators and Attachments
- Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
- Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame
- Space heater
- Differential current transformers (DCT)
- Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
- Generator conversion
- Differential current transformers (DCT) 8.7 kV and 15 kV classes
- Thermostat for space heater
- Alternator air cleaner
- High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
- High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
- Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
Extended Service Contract (ESC)
- Extended Service Contract (ESC): [ ] 2 Year [ ] 3 Year [ ] 5 Year
Instrumentation
- Pyrometer and thermocouples
Lubrication System
- Lube oil in standard sump
- Prelube pumps
- Oil level regulator
Mounting System
- Puck style low efficiency isolators
- Spring type vibration isolators
- IBC vibration isolators
Power Connections
- Right side power connections
- Ground cables between generator and terminal box
- 2700 Frame, four lead, four terminal
- Neutral ground connections
- Rear power connections
- Low voltage Circuit breakers
- Center post busbars
- Left side power connections
Special Tests / Reports
- PGS Test report @ 0.8 power factor
- PGS Test report @ 1.0 power factor
- Canadian Standards Association certification
- Standard engine test charge
- IBC Certification
- Generator set fuel consumption test
- OSHPD Certification
- Generator test report
- Torsional vibration analysis reports
- Fuel consumption test
Starting and Charging
- 10, 20, 35 and 50 Amp Battery chargers
- 24 Volt battery set - Dry
- Electric starting motors
- Air starting motors
- Starter cover
- Engine barring device
- Air pressure regulator
- Jacket water heaters
Extended Service Coverage
- Platinum, Gold and Silver coverage