Standby Rating
605 kVA

Frequency
50 Hz

Emissions/Fuel Strategy
Low BSFC

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

605 kVA Diesel Generator Set

Producing reliable power 605 kVA at 50 Hz, our DE605 GC generator set powerd by C15 diesel engine designed to ISO 8528-5 transient response requirements.

Benefits

Control System

Designed to match engine and alternator performance

Monitoring

Cat Connect option ensures your generator set is always ready to start and performing as expected

Lower Fuel Consumption

Longer run times between fuel fills; reduced operating costs

Features at a Glance

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
A-Frame Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP 1.3 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Full Specifications

Generator Set Specifications

Standby Rating
605 kVA

Frequency
50 Hz

Emissions/Fuel Strategy
Low BSFC

Voltage
380 to 415 Volts

Speed
1500 rpm

Duty Cycle
Standby

Engine Specifications

Engine Model
C15 In-line 6, 4-cycle diesel

Bore
5.4 in

Stroke
6.8 in

Displacement
928 in³

Compression Ratio
16.1:1

Aspiration
Turbocharged Air-to-Air Aftercooled

Fuel System
EUI

Governor Type
Adem™A4

Generator Set Dimensions

Length - Maximum
131 in

Width - Maximum
60.6 in

Height - Maximum
86.1 in

Dry Weight - Genset (maximum)
8120 lb

Equipment

Standard Equipment

Engine

  • Cat® C15 Inline 6 cylinder, 4 stroke diesel

Control Panels

  • GCCP 1.1

Air Inlet

  • Air cleaner

Governor

  • Mechanical governor

Alternator

  • A Frame standard alternator

Cooling

  • Package mounted radiator

Fuel Storage

  • Single wall 8 hour fuel tank

Cooling System

  • Caterpillar extended life coolant
  • Radiator and cooling fan with guards
  • Fan drive, battery charging alternator drive

Electrical Options

  • 3 Pole Circuit breaker
  • Neutral earth link
  • 24 Volt battery with rack and cables

Fuel

  • Secondary fuel filters
  • Fuel priming pump
  • Primary fuel filter with integral water separator

Air inlet system

  • Air cleaner; light duty with disposable element

Generator

  • IP23 Protection
  • Matched to the performance and output characteristics of Cat engines
  • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time

Lube system

  • Lubricating oil
  • Oil drain line with valve

Mounting system

  • Captive linear vibration isolators
  • Lifting provision and drag points

General

  • Engine and alternator pre paint, Caterpillar yellow
  • Engine and alternator pre paint, Caterpillar yellow

Power Termination

  • Busbar

Generator and Attachments

  • Power center, IP22
  • Segregated low voltage (AC/DC) wiring panel
  • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre

Mounting

  • Rubber vibration isolators

Governing System

  • Cat electronic governor (ADEM A4).

Lube System

  • Oil cooler
  • Oil drain valves

Mounting System

  • Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines
Optional Equipment

Exhaust

  • Industrial, residential, critical mufflers

Control panel

  • Speed and Voltage adjust potentiometers
  • PLG 4G/3G/Ethernet
  • Annunciator
  • Emergency E-Stop

Enclosure

  • Cat GC enclosure

Generator

  • Anti-condensation heater
  • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
  • Oversize and premium generators

Electrical Options

  • 4 Pole Circuit breaker
  • Auxiliary contacts
  • Padlockable circuit breaker
  • Battery charger
  • Wet battery

Power Termination

  • Circuit breakers, IEC compliant
  • Circuit breakers, UL listed

Alternator

  • Space heater
  • AVR

Fuel System

  • Dual wall 8 hour fuel tank
  • Single wall 8 hour fuel tank with spill containment
  • Low fuel level shutdown
  • Low and high fuel level alarms
  • Manual fuel transfer pump
  • Fuel transfer system controls
  • Dual wall fuel tank base

Generator and Attachments

  • Oversize A Frame generator
  • LC frame CIP generator
  • Permanent magnet excitation (PMG) generator
  • Space heaters
  • Ingress protection
  • LC frame generator
  • A Frame generator - IP21 Protection
  • CIP A Frame generator
  • Oversize LC frame generator

Starting/Charging

  • Charging alternator
  • Jacket water heater
  • Battery chargers
  • Oversize batteries
  • Heavy duty starting system
  • 24 Volt battery with rack and cables

Air inlet system

  • Single stage air filter
  • Dual element air filter

Certifications

  • EU Certificate of Conformance (CE)
  • EAC Certification

General

  • Automatic transfer switches (ATS)
  • EEC Declaration of Conformity
  • Integral & sub-base UL listed dual wall fuel tanks
  • Single or dual wall sub-base fuel tanks
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • CSA Certification
  • UL 2200 package
  • The following options are based on regional and product configuration:
  • Single or dual wall integral fuel tanks
  • EU Certificate of Conformance (CE)
  • Sound attenuated, weather protective or high ambient weather protective enclosure
  • Narrow, wide or skid base

Extended service coverage

  • 3, 4, 5 and 10 Years

Enclosures

  • High ambient sound attenuated enclosures

Exhaust System

  • Industrial silencer
  • 10 dBA Attenuation silencer
  • Manifold and turbocharger guards
  • End in/end out mufflers - 10, 25 and 35 dBA attenuation
  • Flexible exhaust fittings
  • 6 and 8 inch elbow kit
  • 6 and 8 inch flange GP
  • Engine mounted muffler

Lube System

  • Manual sump pump

Mounting System

  • Narrow skid base - replaces standard fuel tank base

Special Test / Reports

  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8 power factor

Starting / Charging System

  • 5 Amp single Battery charger
  • Battery disconnect switch
  • Jacket water heater

Similar New Power Solutions

C1.1 Generator Set
Diesel Generator Sets

C1.1 Generator Set

Standby Rating: 7.5/9.5 kVA
Prime Power Rating: 6.8/8.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C1.5 Generator Set
Diesel Generator Sets

C1.5 Generator Set

Standby Rating: 11/12/13.5/16 kVA
Prime Power Rating: 10/11/12.5/14.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C3.3 Generator Set
Diesel Generator Sets

C3.3 Generator Set

Standby Rating: 26/33/40/50 kVA
Prime Power Rating: 24/30/36/45 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage II / EU Stage IIIA

C2.2 Generator Set
Diesel Generator Sets

C2.2 Generator Set

Standby Rating: 14/16.5/18/22 kVA
Prime Power Rating: 13/15/16.5/20 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C4.4 Generator Set
Diesel Generator Sets

C4.4 Generator Set

Standby Rating: 55/65/88/90/110 kVA
Prime Power Rating: 50/60/80/82/100 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIA / EU Stage IIIA

C7.1 ACERT
Diesel Generator Sets

C7.1 ACERT

Standby Rating: 150/165/175/200/220 kVA
Prime Power Rating: 135/150/160/180/200 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIIA

3512B Diesel Generator Set
Diesel Generator Sets

3512B Diesel Generator Set

Standby Rating: 1625/1600/1500 kVA
Prime Power Rating: 1500/1360 kVA
Emissions/Fuel Strategy: Low Fuel , Low Emissions

3512 Generator Set
Diesel Generator Sets

3512 Generator Set

Standby Rating: 1400/1250 kVA
Prime Power Rating: 1275/1150 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516B Generator Set
Diesel Generator Sets

3516B Generator Set

Standby Rating: 2250 kVA
Prime Power Rating: 2000 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516 Diesel Generator Set
Diesel Generator Sets

3516 Diesel Generator Set

Standby Rating: 2000 kVA
Prime Power Rating: 1825 kVA
Emissions/Fuel Strategy: Low Fuel Consumption