DE600S GC Generator Set
Diesel Generator Sets
Details
Standby Rating
600 ekW
Frequency
60 Hz
Emissions/Fuel Strategy
Low BSFC
Overview
600 kW Diesel Generator Set
Producing reliable power 600 kW at 60 Hz, our DE600S GC generator set powerd by C15 diesel engine designed to ISO 8528-5 transient response requirements.
Benefits
Control System
- Track Genset Health and Operation Parameters
- Genset Utilization and Performance Tracking
Fuel Consumption
Monitoring
Cat Connect option ensures your generator set is always ready to start and perform as expected
Features at a Glance
- Cat Generator Set Package
-
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
- Cat Diesel Engine
-
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
- A-Frame Alternator
-
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
- GCCP1.2 Control Panel
-
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
- Cooling System
-
- Designed to operate in standard ambient temperatures up to 55°C (131°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
- Certifications
-
- CE Certification Available
- CIS Certification Available
- One Safe Source
-
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
- Worldwide Product Support
-
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Specifications
Full Specifications
- Generator Set Specifications
-
Standby Rating
600 ekWFrequency
60 HzEmissions/Fuel Strategy
Low BSFCVoltage
220 to 480 VoltsSpeed
1800 RPMDuty Cycle
Standby
- Engine Specifications
-
Engine Model
C15 In-line 6, 4-cycle dieselBore
5.4 inStroke
6.8 inDisplacement
928 in³Compression Ratio
16.1:1Aspiration
Turbocharged Air-to-Air AftercooledFuel System
EUIGovernor Type
Adem™A4
- Generator Set Dimensions
-
Length - Maximum
131 inWidth - Maximum
60.6 inHeight - Maximum
86.1 inDry Weight - Genset (maximum)
8364 lb
Equipment
- Standard Equipment
-
Engine
- Cat® C15 Inline 6 cylinder, 4 stroke diesel
Air Inlet
- Air cleaner
Control Panels
- GCCP 1.1
Governor
- Mechanical governor
Cooling
- Package mounted radiator
Alternator
- A Frame standard alternator
Control Panel
- EMCP 4 Genset controller
Fuel Storage
- Single wall 8 hour fuel tank
Cooling System
- Radiator and cooling fan with guards
- Fan drive, battery charging alternator drive
Fuel
- Fuel priming pump
- Primary fuel filter with integral water separator
- Secondary fuel filters
Exhaust
- Exhaust flange outlet
Electrical Options
- 3 Pole Circuit breaker
- Neutral earth link
- 24 Volt battery with rack and cables
Air inlet system
- Air cleaner; light duty with disposable element
Lube system
- Lubricating oil
- Oil drain line with valve
Generator
- Matched to the performance and output characteristics of Cat engines
- IP23 Protection
- Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
Mounting system
- Captive linear vibration isolators
- Lifting provision and drag points
General
- Engine and alternator pre paint, Caterpillar yellow
- Engine and alternator pre paint, Caterpillar yellow
- Paint - Caterpillar yellow except rails and radiators gloss black
Power Termination
- Busbar
Generator and Attachments
- Power center, IP22
- Optional LC Frame generator - IP23 Protection
- Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
- Integrated voltage regulator (IVR)
- Segregated low voltage (AC/DC) wiring panel
Mounting
- Rubber vibration isolators
Governing System
- Cat electronic governor (ADEM A4).
Lube System
- Oil drain valves
- Oil cooler
Mounting System
- Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines
Starting/Charging
- 24 volt starting motor
- Batteries
- 24 Volt battery with rack and cables
- Optional Equipment
-
Exhaust
- Industrial, residential, critical mufflers
Control panel
- Speed and Voltage adjust potentiometers
- PLG 4G/3G/Ethernet
- Annunciator
- Emergency E-Stop
Enclosure
- Cat GC enclosure
Generator
- Oversize and premium generators
- Anti-condensation heater
- Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
Power Termination
- Circuit breakers, UL listed
- Circuit breakers, IEC compliant
Electrical Options
- 4 Pole Circuit breaker
- Auxiliary contacts
- Padlockable circuit breaker
- Battery charger
- Wet battery
Alternator
- Space heater
- AVR
Fuel System
- Dual wall 8 hour fuel tank
- Single wall 8 hour fuel tank with spill containment
- Low fuel level shutdown
- Low and high fuel level alarms
- Manual fuel transfer pump
- Fuel transfer system controls
- Optional BS799 Compliant Integral Dual wall fuel tank base
Starting/Charging
- Jacket water heater
- Heavy duty starting system
- Battery chargers
- Charging alternator
- Oversize batteries
Air inlet system
- Single stage air filter
- Dual element air filter
Certifications
- EU Certificate of Conformance (CE)
- EAC Certification
Extended service coverage
- 3, 4, 5 and 10 Years
General
- The following options are based on regional and product configuration:
- Single or dual wall integral fuel tanks
- Narrow, wide or skid base
- Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
- EU Certificate of Conformance (CE)
- CSA Certification
- EEC Declaration of Conformity
- Integral & sub-base UL listed dual wall fuel tanks
- UL 2200 package
- Sound attenuated, weather protective or high ambient weather protective enclosure
- Automatic transfer switches (ATS)
- Single or dual wall sub-base fuel tanks
Enclosures
- High ambient sound attenuated enclosures
Exhaust System
- Industrial silencer
- 10 dBA Attenuation silencer
- Flexible exhaust fittings
- 6 and 8 inch elbow kit
- End in/end out mufflers - 10, 25 and 35 dBA attenuation
- Engine mounted muffler
- Manifold and turbocharger guards
- 6 and 8 inch flange GP
Generator and Attachments
- Oversize A Frame generator
- Permanent magnet excitation (PMG) generator
- Oversize LC frame generator
- Ingress protection
- LC frame generator
- Space heaters
- LC frame CIP generator
- CIP A Frame generator
Lube System
- Manual sump pump
Mounting System
- Narrow skid base - replaces standard fuel tank base
Special Test / Reports
- PGS Test report @ 1.0 power factor
- PGS Test report @ 0.8 power factor
Starting / Charging System
- 5 Amp single Battery charger
- Battery disconnect switch