DE550 GC (50 Hz) Generator Set
Diesel Generator Sets
Details
Standby Rating
550 kVA
Frequency
50 Hz
Emissions/Fuel Strategy
Low BSFC
Overview
550 kVA Diesel Generator Set
Producing reliable power 550 kVA at 50 Hz, our DE550 GC generator set powerd by C13 diesel engine designed to ISO 8528-5 transient response requirements.
Benefits
Control System
- Track Genset Health and Operation Parameters
- Genset Utilization and Performance Tracking
Monitoring
Cat Connect option ensures your generator set is always ready to start and perform as expected
Lower Fuel Consumption
Longer run times between fuel fills; reduced operating costs
Features at a Glance
- Cat Generator Set Package
-
- Cat generator set packages have been fully prototype tested
- Accepts 100% block load in one step and meets NFPA 110 loading requirements
- Conform to ISO 8528-5 steady state and transient response requirements
- Cat Diesel Engine
-
- Reliable, rugged, durable design
- Field-proven in thousands of applications worldwide
- Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
- A-Frame Alternator
-
- Superior motor starting capability minimizes need for oversizing alternator
- Designed to match performance and output characteristics of Cat diesel engines
- Robust Class H insulation
- GCCP 1.1 Control Panel
-
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirement
- Expansion modules and site-specific programming for specific customer requirements
- Cooling System
-
- Designed to operate in standard ambient temperatures up to 55°C (131°F)
- Contact your Cat Dealer for specific ambient and altitude capabilities
- Certifications
-
- CE Certification Available
- CIS Certification Available
- One Safe Source
-
- Components used in the generator set are selected based on seamless design integration to provide the optimum performance
- The generator set is fully assembled at a Caterpillar facility following our quality guidelines
- Each generator set package is tested before leaving the Caterpillar facility
- Cat product support, including dealer service, parts and warranty covers the entire Cat power system
- Worldwide Product Support
-
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Specifications
Full Specifications
- Generator Set Specifications
-
Standby Rating
550 kVAFrequency
50 HzEmissions/Fuel Strategy
Low BSFCVoltage
380 to 415 VoltsSpeed
1500 rpmDuty Cycle
Standby
- Engine Specifications
-
Engine Model
C13 In-line 6, 4-cycle dieselBore
5.1 inStroke
6.2 inDisplacement
763 in³Compression Ratio
15.8:1Aspiration
Turbocharged Air-to-Air AftercooledFuel System
EUIGovernor Type
Adem™A4
- Generator Set Dimensions
-
Length - Maximum
122 inWidth - Maximum
52.7 inHeight - Maximum
85.4 inDry Weight - Genset (maximum)
6693 lb
Equipment
- Standard Equipment
-
Engine
- Cat® C13 Inline 6 cylinder, 4 stroke diesel
Control Panels
- GCCP 1.1
Governor
- Mechanical governor
Alternator
- A Frame standard alternator
Fuel Storage
- Single wall 8 hour fuel tank
Cooling System
- Radiator and cooling fan with guards
- Fan drive, battery charging alternator drive
Electrical Options
- 3 Pole Circuit breaker
- Neutral earth link
- 24 Volt battery with rack and cables
Air inlet system
- Air cleaner; light duty with disposable element
Lube system
- Lubricating oil
- Oil drain line with valve
Mounting system
- Captive linear vibration isolators
- Lifting provision and drag points
Generator and Attachments
- Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
Packaged Generator Set
- Coolant drain line with valve
- Radiator package mounted
- Service indicator
- Low coolant level sensor
- Disposable air filter
- Coolant level sight gauge
Governing System
- Cat electronic governor (ADEM A4)
Lube System
- Oil drain valves
- Oil cooler
- Lubricating oil
Mounting System
- Captive linear vibration isolators between base and engine-generator
- Includes lifting provisions and termination points for coolant and lube oil drain lines
Starting / Charging System
- 24V battery with rack and cables
General
- Engine and alternator pre paint, Caterpillar yellow
- Engine and alternator pre-paint, Caterpillar yellow
- Optional Equipment
-
Control panel
- Speed and Voltage adjust potentiometers
- PLG 4G/3G/Ethernet
- Annunciator
- Emergency E-Stop
Enclosure
- Cat GC enclosure
Electrical Options
- 4 Pole Circuit breaker
- Auxiliary contacts
- Padlockable circuit breaker
- Battery charger
- Wet battery
Circuit breakers
- Circuit breaker (IEC) Auxiliary contacts
- Shunt trip for IEC circuit breaker
- 4 Pole (IEC-100% rated) Circuit breaker - Motorised
Alternator
- Space heater
- AVR
Fuel System
- Dual wall 8 hour fuel tank
- Single wall 8 hour fuel tank with spill containment
- Low fuel level shutdown
- Low and high fuel level alarms
- Manual fuel transfer pump
- Integral dual wall fuel tank base
- Fuel transfer system controls
Air inlet system
- Single stage air filter
- Dual element air filter
Certifications
- EU Certificate of Conformance (CE)
- EAC Certification
Extended service coverage
- 3, 4, 5 and 10 Years
Exhaust System
- Industrial silencer
- 10 dBA Attenuation silencer
- Flexible 8 inch exhaust fittings
- 10, 25 and 35 dBA attenuation
- 6 and 8 inch flange GP
- 6 and 8 inch elbow kit
Generator and Attachments
- A Frame oversize generator
- A Frame CIP generator
- Permanent magnet excitation (PMG) generator
- Ingress protection
- LC CIP generator
- LC frame generator
- Space heaters
Lube System
- Manual sump pump
Mounting System
- Narrow skid base
starting / Charging System
- 5 Amp single Battery charger
- Battery disconnect switch
- Jacket water heater