D250 GC (60 Hz) Generator Set

Diesel Generator Sets

Details

Standby Rating
250 ekW

Frequency
60 Hz

Emissions/Fuel Strategy
U.S. EPA Tier 3 Certified

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

250 ekW Diesel Generator Set

Producing reliable power of 250 ekW at 60 Hz, our D250 GC diesel generator set are designed to ISO 8528-5 transient response requirements. The D250 GC generator sets are engineered to EPA Stationary Emergency (Tier 3) emissions standards.

Benefits

Installed Space

Requires less space for installation; leaves more room for your on-going operations

Less

Easier handling; less structural reinforcement required to support genset weight

Alternator Temperature Rise

Meets most all specifications; ensures long alternator life

Features at a Glance

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
M-Frame Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP 1.2 Control Panel
  • User-friendly interface and navigation
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to104°F (40°C)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • UL 2200 Listed
  • ULC Certification Available
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Full Specifications

Generator Set Specifications

Standby Rating
250 ekW

Frequency
60 Hz

Emissions/Fuel Strategy
U.S. EPA Tier 3 Certified

Voltage
208 to 600 Volts

Speed
1800 rpm

Duty Cycle
Standby

Engine Specifications

Engine Model
Cat® C9 In-line 6, 4-cycle Diesel

Bore
4.4 in

Stroke
5.9 in

Displacement
538 in³

Compression Ratio
16.3:1

Aspiration
Turbocharged Air-to-Air Aftercooled

Fuel System
HEUI

Governor Type
Adem™A4

Generator Set Dimensions

Length - Maximum
155.5 in

Width - Minimum
56.3 in

Width - Maximum
56.7 in

Height - Minimum
67.2 in

Height - Maximum
86.7 in

Dry Weight - Genset (minimum)
5324.2 lb

Dry Weight - Genset (maximum)
6735.1 lb

Equipment

Standard Equipment

Air Inlet System

  • Air cleaner - Non canister, disposable
  • Aftercooler core
  • Turbocharger

Control Panel

  • GCCP 1.2

Cooling System

  • Jacket water pump, gear driven, centrifugal
  • Radiator sight gauge
  • Blower fan and fan drive with guards
  • Thermostats and housing
  • Coolant drain valve
  • Radiator, package mounted

Exhaust System

  • Exhaust manifold - dry

Fuel System

  • Fuel priming pump
  • Engine fuel transfer pump
  • Primary fuel filter w/integral water separator and secondary filter, spin on
  • Integral tank base, 24 hours, UL142

Generator Set

  • Factory tested to design specifications at full load conditions
  • Complete system designed & built at ISO 9001:2000 certified facilities
  • All protective devices and control functions simulated and checked

Generators and Generator Attachments

  • Easy access to AVR and terminals
  • Insulation system, Class H
  • Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
  • Voltage regulator (single phase sensing)
  • Terminal box, IP22 RHS facing, bottom cable entry
  • 12 Leads
  • Standard winding protection for non-harsh environments with relative humidity ? 95%
  • IP23 Protection

Governing System

  • Cat electronic governor (ADEM A4)

Lube System

  • Oil filler and dipstick
  • Lubricating oil, CK-4 (10W-30)
  • Shallow oil pan
  • Oil filter, spin on
  • Fumes disposal to front of radiator
  • Oil cooler
  • Oil drain with valve

Mounting System

  • Includes lifting provisions and termination points for coolant and lube oil drain lines
  • Captive linear vibration isolators between base and engine-generator

Protection

  • Safety shutoff - Overspeed
  • Safety shutoff - High water temperature
  • Safety shutoff - Low oil pressure

Starting/Charging System

  • 24-volt electric starting motor
  • 24V, 45 Amp Charging alternator

General

  • Vibration damper
  • Lifting eyes
  • Parts book
Optional Equipment

Air Inlet System

  • Air cleaner (Non canister disposable)

Bases, Mounting & Fuel Tanks

  • Integral tank base, 24 hours, UL142
  • Audio & visual fuel alarm (@90% fuel level)
  • Wide Base - Skid
  • Fuel tank pill pipe & lockable cap

Circuit breaker

  • 400A LS/I
  • 600A LS/I
  • 1200A LSI
  • 600A LSI
  • 1200A LS/I
  • Auxiliary contacts
  • 400A LSI
  • 800A LSI
  • 800A LS/I

Control System

  • Twist release, Red button emergency stop
  • Product link remote monitoring hardware
  • 16 -light NFPA 99/110 Annunciator
  • Volt free contacts
  • Ground fault relay
  • 20A GFCI (Ground Fault Circuit Interrupter)
  • Audible alarm Gp
  • 100A Load center

Enclosures

  • E-Stop
  • AC & DC Source lights
  • Sound attenuated Level 2 enclosure (White)

Exhaust System

  • 6" Muffler - 25 dBA attenuation
  • Flexible exhaust connection
  • Manifold and turbocharger guards

Generator

  • Permanent magnet excitation (PMG) generator
  • Space heater

Starting System

  • Standard battery set: 1000 CCA, 90 amp/hr.
  • Battery charger (UL Certified)
  • Jacket water heater

General

  • CSA Certification
  • Extended Service Coverage
  • Generator test report
  • UL2200 Certification

Similar New Power Solutions

C1.1 Generator Set
Diesel Generator Sets

C1.1 Generator Set

Standby Rating: 7.5/9.5 kVA
Prime Power Rating: 6.8/8.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C1.5 Generator Set
Diesel Generator Sets

C1.5 Generator Set

Standby Rating: 11/12/13.5/16 kVA
Prime Power Rating: 10/11/12.5/14.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C3.3 Generator Set
Diesel Generator Sets

C3.3 Generator Set

Standby Rating: 26/33/40/50 kVA
Prime Power Rating: 24/30/36/45 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage II / EU Stage IIIA

C2.2 Generator Set
Diesel Generator Sets

C2.2 Generator Set

Standby Rating: 14/16.5/18/22 kVA
Prime Power Rating: 13/15/16.5/20 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C4.4 Generator Set
Diesel Generator Sets

C4.4 Generator Set

Standby Rating: 55/65/88/90/110 kVA
Prime Power Rating: 50/60/80/82/100 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIA / EU Stage IIIA

C7.1 ACERT
Diesel Generator Sets

C7.1 ACERT

Standby Rating: 150/165/175/200/220 kVA
Prime Power Rating: 135/150/160/180/200 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIIA

3512B Diesel Generator Set
Diesel Generator Sets

3512B Diesel Generator Set

Standby Rating: 1625/1600/1500 kVA
Prime Power Rating: 1500/1360 kVA
Emissions/Fuel Strategy: Low Fuel , Low Emissions

3512 Generator Set
Diesel Generator Sets

3512 Generator Set

Standby Rating: 1400/1250 kVA
Prime Power Rating: 1275/1150 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516B Generator Set
Diesel Generator Sets

3516B Generator Set

Standby Rating: 2250 kVA
Prime Power Rating: 2000 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516 Diesel Generator Set
Diesel Generator Sets

3516 Diesel Generator Set

Standby Rating: 2000 kVA
Prime Power Rating: 1825 kVA
Emissions/Fuel Strategy: Low Fuel Consumption