D175 GC Generator Set

Diesel Generator Sets

Details

Standby Rating
175 ekW

Frequency
60 Hz

Emissions/Fuel Strategy
U.S. EPA Tier 3 Certified

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

175 ekW Diesel Generator Set

Producing reliable power of 175 ekW at 60 Hz, our D175 GC diesel generator sets designed to ISO 8528-5 transient response requirements. All D175 GC generator sets are available with a choice of emissions levels.

Benefits

Installed Space

Requires less space for installation; leaves more room for your on-going operations

Hours

Ensures you can count on emergency power when it is needed

Fulfillment within 24 hours

World's best product support network ensures spare parts are readily available for maintenance and service needs

Features at a Glance

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
M-Frame Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP 1.2 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • UL 2200 Listed
  • ULC Certification Available
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Full Specifications

Generator Set Specifications

Standby Rating
175 ekW

Frequency
60 Hz

Emissions/Fuel Strategy
U.S. EPA Tier 3 Certified

Voltage
208 to 600 Volts

Speed
1800 rpm

Duty Cycle
Standby

Engine Specifications

Engine Model
C7.1 I-6, 4-Cycle Diesel

Bore
4.1 in

Stroke
5.31 in

Displacement
427.8 in³

Compression Ratio
16.7:1

Aspiration
Turbocharged, Air to Air Aftercooled

Fuel System
Electronic, Common Rail

Governor Type
ADEM™A4

Generator Set Dimensions

Length - Maximum
103.7 in

Width - Maximum
51.2 in

Height - Maximum
58.7 in

Dry Weight - Genset (maximum)
3741 lb

Equipment

Standard Equipment

Air Inlet System

  • Air cleaner; light duty with disposable element

Control Panels

  • GCCP 1.2 Control panel

Cooling System

  • Coolant drain line with valves
  • Fan drive, battery charging alternator drive
  • Caterpillar extended life coolant
  • Radiator and cooling fan with guards

Generator and Generator Attachments

  • Tower panel, IP22, bottom cable entry
  • IP23 Protection
  • 12 Leads
  • Circuit breaker, IEC, 3 pole, mounted in tower panel
  • Segregated low voltage (AC/DC) wiring panel
  • Voltage regulator (single phase sensing)

Exhaust System

  • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose

Fuel System

  • Base, formed steel with single wall integral 24-hour fuel tank
  • Standard open set fuel tank/base supplied

Lube System

  • Lubricating oil
  • Oil drain line with valve

Mounting System

  • Termination points for coolant and lube oil drain lines
  • Includes lifting provision and drag points
  • Captive linear vibration isolators between base and engine-generator

Starting / Charging System

  • 24V battery with rack and cables

Governing System

  • Mechanical and electrical governing system - model dependent

General

  • Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment

Alternator System

  • Permanent magnet excitation (PMG)
  • Quatrature droop king
  • Alternator removal
  • 3 Phase sensing
  • R Frame auxiliary winding: R2273L4 SE aux alt 07, aux alt 08 and aux alt 10
  • Anti-condensation heater
  • Optional LC Frame alternator with coastal insulation protection

Circuit breakers

  • Padlockable breaker device
  • 4 Pole 250A, 400A and 630A Circuit breakers

Control Panel Options

  • Earth fault (2 wire only)
  • Speed adjust contacts
  • Panel mounted audible alarm
  • Volt free contacts
  • Earth leakage (2 wire only)
  • Overload shutdown via breaker
  • Control panel heater
  • Speed adjust potentiometer
  • Battery charger
  • Emergency stop with key

Control System

  • Static battery charger
  • Volt free contacts for common alarm
  • Volt free contacts for generator set running
  • GCCP 1.2

Cooling System

  • Low coolant temperature
  • Coolant heater
  • Low coolant level shutdown

Enclosures

  • Sound attenuated level 2 enclosure

Mounting Options

  • Electronic governor
  • Silencer installation kit
  • Industrial silencer removal
  • Battery removal
  • Residential silencer

Fuel Systems

  • Low fuel level alarm
  • Compact skidbase for open sets
  • DEFRA bunded fuel tank
  • Open set narrow tankbase
  • Low fuel level shutdown
  • Skidbase for CALG enclosure sets
  • High fuel level alarm

Test Reports

  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8 power factor

General

  • Stone guards/radiator trans flange

Global Certifications

  • Certification for CIS

Power Termination

  • Circuit breaker, IEC, 4 pole

Accessories / Miscellaneous

  • Packing case - compact set
  • Packing case - canopied set

Similar New Power Solutions

C1.1 Generator Set
Diesel Generator Sets

C1.1 Generator Set

Standby Rating: 7.5/9.5 kVA
Prime Power Rating: 6.8/8.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C1.5 Generator Set
Diesel Generator Sets

C1.5 Generator Set

Standby Rating: 11/12/13.5/16 kVA
Prime Power Rating: 10/11/12.5/14.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C3.3 Generator Set
Diesel Generator Sets

C3.3 Generator Set

Standby Rating: 26/33/40/50 kVA
Prime Power Rating: 24/30/36/45 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage II / EU Stage IIIA

C2.2 Generator Set
Diesel Generator Sets

C2.2 Generator Set

Standby Rating: 14/16.5/18/22 kVA
Prime Power Rating: 13/15/16.5/20 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C4.4 Generator Set
Diesel Generator Sets

C4.4 Generator Set

Standby Rating: 55/65/88/90/110 kVA
Prime Power Rating: 50/60/80/82/100 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIA / EU Stage IIIA

C7.1 ACERT
Diesel Generator Sets

C7.1 ACERT

Standby Rating: 150/165/175/200/220 kVA
Prime Power Rating: 135/150/160/180/200 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIIA

3512B Diesel Generator Set
Diesel Generator Sets

3512B Diesel Generator Set

Standby Rating: 1625/1600/1500 kVA
Prime Power Rating: 1500/1360 kVA
Emissions/Fuel Strategy: Low Fuel , Low Emissions

3512 Generator Set
Diesel Generator Sets

3512 Generator Set

Standby Rating: 1400/1250 kVA
Prime Power Rating: 1275/1150 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516B Generator Set
Diesel Generator Sets

3516B Generator Set

Standby Rating: 2250 kVA
Prime Power Rating: 2000 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516 Diesel Generator Set
Diesel Generator Sets

3516 Diesel Generator Set

Standby Rating: 2000 kVA
Prime Power Rating: 1825 kVA
Emissions/Fuel Strategy: Low Fuel Consumption