D150 GC Generator Set

Diesel Generator Sets

Details

Standby Rating
150 ekW

Frequency
60 Hz

Emissions/Fuel Strategy
U.S. EPA Tier 3 Certified

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

150 ekW Diesel Generator Set

Producing reliable power of 150 ekW at 60 Hz, our D150 GC diesel generator set is designed to meet ISO 8528-5 transient response requirements.

Benefits

Installed Space

Requires less space for installation; leaves more room for your on-going operations

Hours

Ensures you can count on emergency power when it is needed

Fulfillment within 24 hours

World's best product support network ensures spare parts are readily available for maintenance and service needs

Features at a Glance

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
M-Frame Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP 1.2 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • UL 2200 Listed
  • ULC Certification Available
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Full Specifications

Generator Set Specifications

Standby Rating
150 ekW

Frequency
60 Hz

Emissions/Fuel Strategy
U.S. EPA Tier 3 Certified

Voltage
208 to 600 Volts

Speed
1800 rpm

Duty Cycle
Standby

Engine Specifications

Engine Model
C7.1 I-6, 4-Cycle Diesel

Bore
4.1 in

Stroke
5.31 in

Displacement
428 in³

Compression Ratio
16.7:1

Aspiration
Turbocharged, Air to Air Aftercooled

Fuel System
Electronic, Common Rail

Governor Type
ADEM™A4

Generator Set Dimensions

Length - Maximum
103.7 in

Width - Maximum
51.2 in

Height - Maximum
52.2 in

Dry Weight - Genset (maximum)
3443 lb

Equipment

Standard Equipment

Air Inlet System

  • Air cleaner; light duty with disposable element

Control Panels

  • GCCP 1.2 Control panel

Cooling System

  • Fan drive, battery charging alternator drive
  • Radiator and cooling fan with guards
  • Coolant drain line with valves
  • Caterpillar extended life coolant

Generator and Generator Attachments

  • 12 Leads
  • Segregated low voltage (AC/DC) wiring panel
  • IP23 Protection
  • Tower panel, IP22, bottom cable entry
  • Voltage regulator (single phase sensing)
  • Circuit breaker, IEC, 3 pole, mounted in tower panel

Exhaust System

  • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose

Fuel System

  • Standard open set fuel tank/base supplied
  • Base, formed steel with single wall integral 24-hour fuel tank

Lube System

  • Lubricating oil
  • Oil drain line with valve

Mounting System

  • Termination points for coolant and lube oil drain lines
  • Captive linear vibration isolators between base and engine-generator
  • Includes lifting provision and drag points

Starting / Charging System

  • 24V battery with rack and cables

Governing System

  • Mechanical and electrical governing system - model dependent

General

  • Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment

Alternator System

  • R Frame auxiliary winding: R2273L4 SE aux alt 07, aux alt 08 and aux alt 10
  • Anti-condensation heater
  • 3 Phase sensing
  • Quatrature droop king
  • Alternator removal
  • Permanent magnet excitation (PMG)

Circuit breakers

  • Padlockable breaker device
  • 4 Pole 250A, 400A and 630A Circuit breakers

Control Panel Options

  • Battery charger
  • Panel mounted audible alarm
  • Emergency stop with key
  • Speed adjust potentiometer
  • Control panel heater
  • Earth leakage (2 wire only)
  • Earth fault (2 wire only)
  • Speed adjust contacts
  • Overload shutdown via breaker
  • Volt free contacts

Control System

  • Volt free contacts for common alarm
  • Static battery charger
  • Volt free contacts for generator set running

Cooling System

  • Coolant heater
  • Low coolant level shutdown
  • Low coolant temperature

Enclosures

  • Sound attenuated level 2 enclosure

Mounting Options

  • Electronic governor
  • Residential silencer
  • Industrial silencer removal
  • Silencer installation kit
  • Battery removal

Fuel Systems

  • High fuel level alarm
  • Skidbase for CALG enclosure sets
  • Compact skidbase for open sets
  • Open set narrow tankbase
  • Low fuel level alarm
  • DEFRA bunded fuel tank
  • Low fuel level shutdown

Test Reports

  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8 power factor

General

  • Stone guards/radiator trans flange

Power Termination

  • Circuit breaker, IEC, 4 pole

Accessories / Miscellaneous

  • Packing case - canopied set
  • Packing case - compact set

Similar New Power Solutions

C1.1 Generator Set
Diesel Generator Sets

C1.1 Generator Set

Standby Rating: 7.5/9.5 kVA
Prime Power Rating: 6.8/8.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C1.5 Generator Set
Diesel Generator Sets

C1.5 Generator Set

Standby Rating: 11/12/13.5/16 kVA
Prime Power Rating: 10/11/12.5/14.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C3.3 Generator Set
Diesel Generator Sets

C3.3 Generator Set

Standby Rating: 26/33/40/50 kVA
Prime Power Rating: 24/30/36/45 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage II / EU Stage IIIA

C2.2 Generator Set
Diesel Generator Sets

C2.2 Generator Set

Standby Rating: 14/16.5/18/22 kVA
Prime Power Rating: 13/15/16.5/20 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C4.4 Generator Set
Diesel Generator Sets

C4.4 Generator Set

Standby Rating: 55/65/88/90/110 kVA
Prime Power Rating: 50/60/80/82/100 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIA / EU Stage IIIA

C7.1 ACERT
Diesel Generator Sets

C7.1 ACERT

Standby Rating: 150/165/175/200/220 kVA
Prime Power Rating: 135/150/160/180/200 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIIA

3512B Diesel Generator Set
Diesel Generator Sets

3512B Diesel Generator Set

Standby Rating: 1625/1600/1500 kVA
Prime Power Rating: 1500/1360 kVA
Emissions/Fuel Strategy: Low Fuel , Low Emissions

3512 Generator Set
Diesel Generator Sets

3512 Generator Set

Standby Rating: 1400/1250 kVA
Prime Power Rating: 1275/1150 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516B Generator Set
Diesel Generator Sets

3516B Generator Set

Standby Rating: 2250 kVA
Prime Power Rating: 2000 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516 Diesel Generator Set
Diesel Generator Sets

3516 Diesel Generator Set

Standby Rating: 2000 kVA
Prime Power Rating: 1825 kVA
Emissions/Fuel Strategy: Low Fuel Consumption