D125 GC Generator Set

Diesel Generator Sets

Details

Standby Rating
125 ekW

Frequency
60 Hz

Emissions/Fuel Strategy
U.S. EPA Tier 3 Certified

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

125 ekW Diesel Generator Set

Producing reliable power of 125 ekW at 60 Hz, our D125 GC diesel generator sets designed to ISO 8528-5 transient response requirements. All D125 GC generator sets are available with a choice of emissions levels.

Benefits

Hours

Ensures you can count on emergency power when it is needed

Installed Space

Requires less space for installation; leaves more room for your on-going operations

Fulfillment within 24 hours

World's best product support network ensures spare parts are readily available for maintenance and service needs

Features at a Glance

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
M-Frame Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
GCCP 1.2 Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • UL 2200 Listed
  • ULC Certification Available
One Safe Source
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Full Specifications

Generator Set Specifications

Standby Rating
125 ekW

Frequency
60 Hz

Emissions/Fuel Strategy
U.S. EPA Tier 3 Certified

Voltage
208 to 600 Volts

Speed
1800 rpm

Duty Cycle
Standby

Engine Specifications

Engine Model
C7.1 I-6, 4-Cycle Diesel

Bore
4.1 in

Stroke
5.3 in

Displacement
428 in³

Compression Ratio
16.7:1

Aspiration
Turbocharged, Air to Air Aftercooled

Fuel System
Electronic, Common Rail

Governor Type
ADEM™A4

Generator Set Dimensions

Length - Maximum
103.7 in

Width - Maximum
51.2 in

Height - Maximum
52.2 in

Dry Weight - Genset (maximum)
3099 lb

Equipment

Standard Equipment

Air Inlet System

  • Air cleaner; light duty with disposable element

Control Panels

  • GCCP 1.2 Control panel

Cooling System

  • Fan drive, battery charging alternator drive
  • Coolant drain line with valves
  • Caterpillar extended life coolant
  • Radiator and cooling fan with guards

Generator and Generator Attachments

  • Segregated low voltage (AC/DC) wiring panel
  • IP23 Protection
  • Circuit breaker, IEC, 3 pole, mounted in tower panel
  • Voltage regulator (single phase sensing)
  • Tower panel, IP22, bottom cable entry
  • 12 Leads

Exhaust System

  • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose

Fuel System

  • Base, formed steel with single wall integral 24-hour fuel tank
  • Standard open set fuel tank/base supplied

Lube System

  • Oil drain line with valve
  • Lubricating oil

Mounting System

  • Termination points for coolant and lube oil drain lines
  • Includes lifting provision and drag points
  • Captive linear vibration isolators between base and engine-generator

Starting / Charging System

  • 24V battery with rack and cables

Governing System

  • Mechanical and electrical governing system - model dependent

General

  • Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment

Alternator System

  • Alternator removal
  • Optional LC Frame alternator
  • R Frame auxiliary winding: R2273L4 SE aux alt 07, aux alt 08 and aux alt 10
  • Permanent magnet excitation (PMG)
  • Anti-condensation heater
  • 3 Phase sensing
  • Quatrature droop king

Circuit breakers

  • Padlockable breaker device
  • 4 Pole 250A, 400A and 630A Circuit breakers

Control Panel Options

  • Battery charger
  • Control panel heater
  • Earth fault (2 wire only)
  • Volt free contacts
  • Emergency stop with key
  • Speed adjust potentiometer
  • Earth leakage (2 wire only)
  • Overload shutdown via breaker
  • Speed adjust contacts
  • Panel mounted audible alarm

Control System

  • Volt free contacts for generator set running
  • Volt free contacts for common alarm
  • Static battery charger
  • GCCP 1.2

Cooling System

  • Coolant heater
  • Low coolant temperature
  • Low coolant level shutdown

Enclosures

  • Sound attenuated level 2 enclosure

Mounting Options

  • Silencer installation kit
  • Residential silencer
  • Battery removal
  • Industrial silencer removal
  • Electronic governor

Fuel Systems

  • Low fuel level shutdown
  • Open set narrow tankbase
  • Skidbase for CALG enclosure sets
  • DEFRA bunded fuel tank
  • Low fuel level alarm
  • Compact skidbase for open sets
  • High fuel level alarm

Test Reports

  • PGS Test report @ 0.8 power factor
  • PGS Test report @ 1.0 power factor

General

  • Stone guards/radiator trans flange

Global Certifications

  • Certification for CIS

Power Termination

  • Circuit breaker, IEC, 4 pole

Accessories / Miscellaneous

  • Packing case - compact set
  • Packing case - canopied set

Similar New Power Solutions

C1.1 Generator Set
Diesel Generator Sets

C1.1 Generator Set

Standby Rating: 7.5/9.5 kVA
Prime Power Rating: 6.8/8.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C1.5 Generator Set
Diesel Generator Sets

C1.5 Generator Set

Standby Rating: 11/12/13.5/16 kVA
Prime Power Rating: 10/11/12.5/14.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C3.3 Generator Set
Diesel Generator Sets

C3.3 Generator Set

Standby Rating: 26/33/40/50 kVA
Prime Power Rating: 24/30/36/45 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage II / EU Stage IIIA

C2.2 Generator Set
Diesel Generator Sets

C2.2 Generator Set

Standby Rating: 14/16.5/18/22 kVA
Prime Power Rating: 13/15/16.5/20 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C4.4 Generator Set
Diesel Generator Sets

C4.4 Generator Set

Standby Rating: 55/65/88/90/110 kVA
Prime Power Rating: 50/60/80/82/100 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIA / EU Stage IIIA

C7.1 ACERT
Diesel Generator Sets

C7.1 ACERT

Standby Rating: 150/165/175/200/220 kVA
Prime Power Rating: 135/150/160/180/200 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIIA

3512B Diesel Generator Set
Diesel Generator Sets

3512B Diesel Generator Set

Standby Rating: 1625/1600/1500 kVA
Prime Power Rating: 1500/1360 kVA
Emissions/Fuel Strategy: Low Fuel , Low Emissions

3512 Generator Set
Diesel Generator Sets

3512 Generator Set

Standby Rating: 1400/1250 kVA
Prime Power Rating: 1275/1150 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516B Generator Set
Diesel Generator Sets

3516B Generator Set

Standby Rating: 2250 kVA
Prime Power Rating: 2000 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516 Diesel Generator Set
Diesel Generator Sets

3516 Diesel Generator Set

Standby Rating: 2000 kVA
Prime Power Rating: 1825 kVA
Emissions/Fuel Strategy: Low Fuel Consumption