C32 Generator Set

Diesel Generator Sets

Details

Standby Rating
1100/1250/1400/1500 kVA

Prime Power Rating
1000/1100 kVA

Emissions/Fuel Strategy
Low BSFC

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

910 - 1500 kVA Diesel Generator Set

Producing reliable power from 910 kVA to 1500 kVA at 50 Hz, our C32B diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100 % rated load in one step. Our C32B generator sets are made for demands, so you can make yours.

Benefits

installed space

Requires less space for installation

less

Reduced amount of structural support required

Ambient

Provides full power even on hottest days of the year

Features at a Glance

Cat Generator Set Package

Cat Generator Set Package

        
  • Cat generator set packages have been fully prototype tested
  •     
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  •     
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine

Cat Diesel Engine

        
  • Reliable, rugged, durable design
  •     
  • Field-proven in thousands of applications worldwide
  •     
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator

SR5 Alternator

        
  • Superior motor starting capability minimizes need for oversizing alternator
  •     
  • Designed to match performance and output characteristics of Cat diesel engines
  •     
  • Robust Class H insulation
Control Panel

Control Panel

        
  • User-friendly interface and navigation
  •     
  • Scalable system to meet a wide range of installation requirement
  •     
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System

Cooling System

        
  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  •     
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications

Certifications

        
  • IBC seismic certification
  •     
  • EU Declaration of Conformity
  •     
  • Eurasian Conformity (EAC)
One Safe Source

One Safe Source

        
  • Components used in the generator set are selected at the design stage to provide optimum package performance
  •     
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  •     
  • Each generator set package is tested before leaving the Caterpillar facility
  •     
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support

Worldwide Product Support

        
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  •     
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Full Specifications

Generator Set Specifications

Standby Rating
1100/1250/1400/1500 kVA

Prime Power Rating
1000/1100 kVA

Emissions/Fuel Strategy
Low BSFC

Voltage
400 to 3300 Volts

Frequency
50 Hz

Speed
1500 rpm

Duty Cycle
Standby, Mission Critical, Prime, Continuous

Engine Specifications

Engine Model
C32B TA, V-12, 4-Stroke Water-Cooled Diesel

Bore
5.71 in

Stroke
6.38 in

Displacement
1958.86 in³

Compression Ratio
15.0:1

Aspiration
TA

Fuel System
MEUI

Governor Type
Adem™A4

Generator Set Dimensions

Length - Minimum
164 in

Length - Maximum
176.6 in

Width - Minimum
66.3 in

Width - Maximum
87.8 in

Height - Minimum
85.1 in

Height - Maximum
86.4 in

Dry Weight - Genset (minimum)
14700 lb

Dry Weight - Genset (maximum)
17855 lb

Equipment

Standard Equipment

Air Inlet System

  • Single element canister type with service indicator

Control Panel

  • GCCP 1.2
  • GCCP 1.3
  • Warning shutdowns
  • Control features
  • Communications
  • Programmable protective relaying functions
  • Digital indicators

Cooling System

  • Radiator fan and fan drive
  • Coolant drain line with valve
  • ATAAC
  • Caterpillar extended life coolant
  • Fan and belt guards
  • Low coolant level sensor

Exhaust

  • Exhaust manifold - dry
  • 203 mm (8 in) ID round flanged outlet

Fuel System

  • Primary fuel filter with water separator
  • Secondary fuel filters
  • Fuel cooler
  • Fuel priming pump

Generators and Attachments

  • 6 Lead
  • Salient pole
  • NEMA Class H insulation
  • Internal excitation (IE)
  • Permanent magnet excitation (PMG)
  • Reactive droop
  • 3 Phase brushless
  • Winding temperature detectors
  • Class H temperature rise at 40C ambient
  • Busbar connections, top center mounted, top cable entry
  • IEC standard hole pattern
  • Integrated voltage regulator (IVR)

Governing System

  • ADEM(tm) A4

Mounting System

  • Rubber anti-vibration mounts
  • Rails - engine/generator/radiator mounting

Lube System

  • Gear type lube oil pump
  • Oil filter, filler and dipstick
  • Integral lube Oil cooler
  • Fumes disposal
  • Oil drain lines and valve
  • Lubricating oil

Power Termination

  • Busbar

Starting / Charging System

  • Battery disconnect switch
  • Battery, rack and cables
  • 24 Volt electric starting motor
  • 45 Amp Charging alternator

General

  • Caterpillar yellow with high gloss black rails & radiator
  • Flywheel and flywheel housing-SAE
  • SAE standard rotation
  • RH service
Optional Equipment

Air Inlet System

  • Heavy duty air cleaner
  • Standard air cleaners
  • Dual element air cleaner

Circuit breakers

  • Circuit breaker wiring groups
  • Enclosures - Control packaging
  • Shrouds
  • Power connection covers
  • 1600, 2000, 2500 and 3200 Amp, 3 Pole, IEC-Rated Circuit breakers
  • Center posts busbars
  • Cable supports
  • 400, 800, 1200, 1600, 2000, 2500 and 3000 Amp, 3 Pole, UL-100% Rated Circuit breakers
  • 800, 1600, 2000, 2500 and 3200 Amp, 4 Pole, IEC rated Circuit breakers

Control Panel

  • Cat® ECS 100
  • Cat® ECS 200

Cooling System

  • High ambient radiator
  • Extended life coolant
  • Radiator duct flange
  • Standard radiator
  • Certified radiator

Enclosures

  • Color options
  • Cold weather bundle
  • DC lighting package
  • Sound attenuated enclosure
  • Premium sound attenuated enclosure
  • Enclosure fuel tank options
  • Enclosure louvres - fixed and motorized
  • AC Panel, outlets and lights
  • Panel bracket

Exhaust System

  • Flexible fittings
  • Exhaust through the wall kit
  • Elbow mounting kit
  • Mufflers
  • Flange and exhaust expanders
  • Guard and shield system
  • Flanges
  • All C32B engines have 203 mm (8 in) exhaust outlets

Generator and Attachments

  • Medium voltage generators
  • Low voltage generators

Lube System

  • Prelube manual sump pump
  • Oil pan
  • Oil level regulator

Mounting System

  • IBC vibration isolators
  • Spring type vibration isolators
  • Mounting base types
  • Standard package isolators

Power Termination

  • Circuit breakers, UL listed
  • Circuit breakers, IEC compliant

Power Connections

  • Low voltage connection cables
  • Neutral grounding connection
  • Center post busbars

Starting / Charging System

  • Electric starting motor - Standard/heavy duty
  • Jacket water heater
  • 35 Amp Battery charger
  • 10 Amp Battery charger
  • 10 Amp enclosure Battery charger
  • Standard 24 volt open package battery set - Dry
  • 20 Amp Battery charger
  • Space heater

Special Tests / Reports

  • IBC seismic Certifications
  • Custom generator TVA report
  • PGS Test report @ 1.0 power factor
  • Generator test report
  • Standard engine test
  • Standard genset Torsional Vibration Analysis (TVA) report
  • CSA test and certification
  • OSHPD seismic Certifications
  • PGS Test report @ 0.8 power factor

General

  • Special paint
  • US aid emblem

Similar New Power Solutions

C1.1 Generator Set
Diesel Generator Sets

C1.1 Generator Set

Standby Rating: 7.5/9.5 kVA
Prime Power Rating: 6.8/8.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C1.5 Generator Set
Diesel Generator Sets

C1.5 Generator Set

Standby Rating: 11/12/13.5/16 kVA
Prime Power Rating: 10/11/12.5/14.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C3.3 Generator Set
Diesel Generator Sets

C3.3 Generator Set

Standby Rating: 26/33/40/50 kVA
Prime Power Rating: 24/30/36/45 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage II / EU Stage IIIA

C2.2 Generator Set
Diesel Generator Sets

C2.2 Generator Set

Standby Rating: 14/16.5/18/22 kVA
Prime Power Rating: 13/15/16.5/20 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C4.4 Generator Set
Diesel Generator Sets

C4.4 Generator Set

Standby Rating: 55/65/88/90/110 kVA
Prime Power Rating: 50/60/80/82/100 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIA / EU Stage IIIA

C7.1 ACERT
Diesel Generator Sets

C7.1 ACERT

Standby Rating: 150/165/175/200/220 kVA
Prime Power Rating: 135/150/160/180/200 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIIA

3512B Diesel Generator Set
Diesel Generator Sets

3512B Diesel Generator Set

Standby Rating: 1625/1600/1500 kVA
Prime Power Rating: 1500/1360 kVA
Emissions/Fuel Strategy: Low Fuel , Low Emissions

3512 Generator Set
Diesel Generator Sets

3512 Generator Set

Standby Rating: 1400/1250 kVA
Prime Power Rating: 1275/1150 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516B Generator Set
Diesel Generator Sets

3516B Generator Set

Standby Rating: 2250 kVA
Prime Power Rating: 2000 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516 Diesel Generator Set
Diesel Generator Sets

3516 Diesel Generator Set

Standby Rating: 2000 kVA
Prime Power Rating: 1825 kVA
Emissions/Fuel Strategy: Low Fuel Consumption