C175-20

Diesel Generator Sets

Details

Standby Rating
4000(no fan)/3900 kVA

Prime Power Rating
3600(no fan)/3500 kVA

Emissions/Fuel Strategy
Low Fuel, Low Emissions

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

3150 - 4000 kVA Diesel Generator Set

Producing reliable power from 3150 - 4000 kVA in 50 Hz, our C175-20 diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100% rated load in one step. The generator set is optimized for low fuel consumption or low emissions.

Benefits

Operating hours

at Global locations

units

In the field

Product

Available on the market

Features at a Glance

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
Cat ECS Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • EU Declaration of Conformity
  • EU Declaration of Incorporation
  • Eurasian Conformity (EAC)
  • IBC seismic certification
One Safe Source
  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

Specifications

Full Specifications

Generator Set Specifications

Standby Rating
4000(no fan)/3900 kVA

Prime Power Rating
3600(no fan)/3500 kVA

Emissions/Fuel Strategy
Low Fuel, Low Emissions

Voltage
400 to 11000 Volts

Frequency
50 Hz

Speed
1500 RPM

Duty Cycle
Standby, Mission Critical, Prime, Continuous

Maximum Rating
4000 kVA

Minimum Rating
3150 kVA

Engine Specifications

Engine Model
C175-20 SCAC, V-20, 4-Stroke Water-Cooled Diesel

Bore
6.89 in

Stroke
8.66 in

Displacement
6456.31 in³

Compression Ratio
15.3:1

Aspiration
Turbo Aftercooled

Fuel System
Common Rail

Governor Type
ADEM� A4

Generator Set Dimensions

Length - Minimum
264.2 in

Length - Maximum
330.8 in

Width - Minimum
85.1 in

Width - Maximum
127.8 in

Height - Minimum
87.6 in

Height - Maximum
150.7 in

Dry Weight - Genset (minimum)
55100 lb

Dry Weight - Genset (maximum)
66200 lb

Equipment

Standard Equipment

Air Inlet

  • 4 x Single element canister air cleaners with service indicator(s).

Control Panel

  • Engine cycle crank
  • Oil pressure (psi, kPa or bar)
  • Digital Indicators
  • Coolant temperature
  • Environmental sealed front face
  • Frequency (Hz)
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Text alarm/event descriptions
  • Low coolant level
  • Volts (L-L & L-N)
  • Auto/start/stop control
  • Warning/shutdown Indicators:
  • Emergency stop pushbutton
  • Engine cool-down timer
  • DC volts
  • High coolant temperature
  • Operating hours
  • Low oil pressure
  • Cat ECS 100
  • Amps (per phase & average)
  • 4 Programmable relay Inputs
  • Alarm acknowledge
  • 4 Programmable relay output
  • Failure to start (overcrank)
  • Overspeed
  • Lamp test
  • 24 Volt DC operation
  • Wall mounted controls
  • RPM

Cooling System

  • SCAC cooling
  • Coolant sensors
  • JW Inlet: 6" ANSI / JW Outlet: 5" Cat Flange
  • AC Inlet: 6" ANSI / AC Outlet: 3-1/2" ANSI

Exhaust

  • Dry exhaust manifold
  • Bolted flange (ANSI 6" & DIN 150) with bellow for each turbo (Qty 4). 50 Hz

Fuel

  • Filters x 3
  • Secondary/tertiary fuel filters
  • 4 Micron spin on type
  • 10 Micron spin on type
  • Engine mounted filters x 3
  • Primary fuel filter water/fuel water separator

Generators and Attachments

  • Salient pole
  • RFI suppression
  • Anti-condensation space heater
  • IEC platinum Stator RTDs
  • Form wound
  • NEMA Class H insulation
  • Voltage regulator
  • Reactive droop capability
  • Min/max Exciter limiter
  • 3 Phase voltage sensing
  • Exciter diode monitor
  • 6 Leads
  • 3 Phase brushless
  • Right side extension box, bottom cable entry
  • Permanent magnet excitation (PMG)
  • Class H temperature rise at 40C ambient

Governing System

  • ADEM A4
  • Redundant shutdown (Overspeed protection through a duplicate speed sensing system)

Lube System

  • Oil drain lines and valve
  • Gear type lube oil pump
  • Oil filter, filler and dipstick
  • Integral lube Oil cooler
  • Lubricating oil
  • Fumes disposal

Mounting Systems

  • Rails - Engine/Generator
  • Rubber anti-vibration mounts - shipped loose

Starting / Charging System

  • Batteries and battery rack w/cables
  • Dual 24 volt electric starting motors
  • Battery disconnect switch

General

  • SAE standard rotation
  • Right hand servicing
  • Paint - Caterpillar yellow with high gloss black rails
Optional Equipment

Air Inlet Systems

  • Single element air cleaner

Control Panels

  • EMCP 4.4
  • Controller and MV and HV power connection locations
  • Load share module
  • Controller voltage and current sensing groups
  • Speed adjust
  • Annunciator modules
  • Customer interface options
  • Generator temperature monitoring
  • E-Stop
  • Interconnect harness
  • Generator harness
  • Modbus monitoring of packages
  • Vandal proof panel door

Cooling System

  • Package mounted radiators
  • Remote radiators
  • Fuel cooler

Crankcase Systems

  • Explosive relief valves
  • Crankcase ventilation system

Exhaust System

  • Front housing - Standby or mission critical
  • Front housing - Prime or continuous
  • Exhaust collectors/manifold
  • Mufflers (15, 25 and 34 dBA)

Fuel System

  • Primary fuel filter

Generators and Attachments

  • Medium voltage - 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
  • Thermostat for space heater
  • Generator air cleaner
  • Differential current transformers - (5, 9 and 15 kV Class)

Instrumentation

  • Pyrometer and thermocouples

Lube System

  • Lube oil heater
  • Lube oil heater with Crankcase explosion relief valves
  • Drain group oil pans
  • Lubricating oil
  • Electric prelube pumps
  • Oil filters

Mounting System

  • Rubber anti-vibration mounts
  • Spring type linear vibration isolators
  • IBC vibration isolators - Shipped loose

Special Tests / Reports

  • Generator test report
  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8 power factor
  • Standard genset TVA (Torsional Vibration Analysis) report
  • Custom generator TVA report
  • Special test charge - Engine only
  • Genset fuel consumption test
  • Standard engine test charge

Starting / Charging System

  • 24 Volt electric starting motor
  • Air starting motor
  • Air pressure regulator
  • Starter location covers
  • 24 Volt battery set - Dry
  • 20, 35 and 50 Amp Battery chargers
  • Charging alternators - Dry
  • Jacket water heaters

General

  • Special paint - 3500, Colors (other than Caterpillar yellow or high performance paints)
  • US aid emblem
  • Service tools
  • Engine barring group
  • Manual
  • Engine barring air powered
  • control GP - air powered bar group

Similar New Power Solutions

C1.1 Generator Set
Diesel Generator Sets

C1.1 Generator Set

Standby Rating: 7.5/9.5 kVA
Prime Power Rating: 6.8/8.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C1.5 Generator Set
Diesel Generator Sets

C1.5 Generator Set

Standby Rating: 11/12/13.5/16 kVA
Prime Power Rating: 10/11/12.5/14.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C3.3 Generator Set
Diesel Generator Sets

C3.3 Generator Set

Standby Rating: 26/33/40/50 kVA
Prime Power Rating: 24/30/36/45 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage II / EU Stage IIIA

C2.2 Generator Set
Diesel Generator Sets

C2.2 Generator Set

Standby Rating: 14/16.5/18/22 kVA
Prime Power Rating: 13/15/16.5/20 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C4.4 Generator Set
Diesel Generator Sets

C4.4 Generator Set

Standby Rating: 55/65/88/90/110 kVA
Prime Power Rating: 50/60/80/82/100 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIA / EU Stage IIIA

C7.1 ACERT
Diesel Generator Sets

C7.1 ACERT

Standby Rating: 150/165/175/200/220 kVA
Prime Power Rating: 135/150/160/180/200 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIIA

3512B Diesel Generator Set
Diesel Generator Sets

3512B Diesel Generator Set

Standby Rating: 1625/1600/1500 kVA
Prime Power Rating: 1500/1360 kVA
Emissions/Fuel Strategy: Low Fuel , Low Emissions

3512 Generator Set
Diesel Generator Sets

3512 Generator Set

Standby Rating: 1400/1250 kVA
Prime Power Rating: 1275/1150 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516B Generator Set
Diesel Generator Sets

3516B Generator Set

Standby Rating: 2250 kVA
Prime Power Rating: 2000 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516 Diesel Generator Set
Diesel Generator Sets

3516 Diesel Generator Set

Standby Rating: 2000 kVA
Prime Power Rating: 1825 kVA
Emissions/Fuel Strategy: Low Fuel Consumption