C175-16 Generator Set

Diesel Generator Sets

Details

Standby Rating
3100(no fan)/3000 kVA

Prime Power Rating
2825(no fan)/2725 kVA

Emissions/Fuel Strategy
Low Fuel, Low Emissions

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

2500 - 3100 kVA Diesel Generator Set

Producing reliable power from 2500 - 3100 kVA at 50 Hz, our 175-16 diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100% rated load in one step. The generator set is optimized for Low Fuel Consumption or Low Emissions.

Benefits

Operating hours

at Global locations

units

In the field

Product

Available on the market

Features at a Glance

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
Cat ECS Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • EU Declaration of Incorporation
  • EU Declaration of Conformity
  • IBC seismic certification
  • Eurasian Conformity (EAC)
One Safe Source
  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Full Specifications

Generator Set Specifications

Standby Rating
3100(no fan)/3000 kVA

Prime Power Rating
2825(no fan)/2725 kVA

Emissions/Fuel Strategy
Low Fuel, Low Emissions

Voltage
380 to 11000 Volts

Frequency
50 Hz

Speed
1500 rpm

Duty Cycle
Standby, Mission Critical, Prime, Continuous

Maximum Rating
3100 kVA

Minimum Rating
2500 kVA

Engine Specifications

Engine Model
C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel

Bore
6.89 in

Stroke
8.66 in

Displacement
5166.88 in³

Compression Ratio
16.7:1

Aspiration
Turbo Aftercooled

Fuel System
Common Rail

Governor Type
ADEM� A4

Generator Set Dimensions

Length - Minimum
251.9 in

Length - Maximum
320.2 in

Width - Minimum
82.7 in

Width - Maximum
109.1 in

Height - Minimum
86.9 in

Height - Maximum
130.1 in

Dry Weight - Genset (minimum)
42750 lb

Dry Weight - Genset (maximum)
50750 lb

Equipment

Standard Equipment

Air Inlet System

  • 4 x Single element canister with service indicator(s)

Control Panel

  • Cat ECS 100
  • Volts (L-L & L-N)
  • Engine cycle crank
  • Power factor (per phase & average)
  • Overcurrent
  • Communications
  • Emergency stop
  • 2 Programmable relay outputs (Form C)
  • 6 Programmable digital inputs
  • 2 Programmable digital outputs
  • Environmental sealed front face.
  • DC Volts
  • Reverse power
  • Programmable protective relaying functions
  • High coolant temperature
  • Accessory module data link
  • Low coolant level
  • Over/under frequency
  • Amps (per phase & average)
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Low coolant temperature
  • Reverse reactive power
  • Controls
  • Oil pressure (psi, kPa or bar)
  • Lamp test
  • Coolant temperature
  • Warning/shutdown Indicators:
  • 4 Programmable relay outputs (Form A)
  • Alarm acknowledge
  • Generator phase sequence
  • 24 Volt DC operation
  • Serial annunciator module data link
  • Customer data link (Modbus RTU)
  • Failure to start (overcrank)
  • Auto/start/stop control.
  • Low oil pressure
  • RPM
  • Text alarm/event descriptions.
  • Digital Indicators
  • Generator mounted - rear facing
  • Emergency stop pushbutton
  • Engine cool-down timer
  • Operating hours
  • Over/under voltage
  • Overspeed
  • Frequency (Hz)

Cooling System

  • Radiator group - shipped loose
  • SCAC cooling
  • Coolant Sensors
  • Coolant drain line and valves
  • Fan and belt guards

Exhaust System

  • Bolted flange, with bellow for each turbo
  • Dry exhaust manifold

Fuel System

  • Filters x 3
  • Secondary/ tertiary fuel filters
  • 10 Micron spin On Type
  • 4 Micron Spin On Type
  • Primary fuel filter water/fuel water separator
  • Engine mounted filters x 3

Generator and Attachments

  • 6 Leads
  • IEC platinum stator RTDs
  • Voltage regulator
  • Reactive droop capability
  • 3 Phase voltage sensing
  • RFI suppression
  • Min / max exciter limiter
  • exciter diode monitor
  • Form wound
  • Permanent magnet excitation (PMG)
  • NEMA Class H insulation
  • Class H temperature rise at 40C ambient
  • (LV) Busbar connections, top/center mounted, top cable entry
  • 3 Phase Brushless
  • Salient pole
  • 50 Hz models: IEC standard hole pattern
  • (MV) Busbar connections, right side extension box, bottom cable entry
  • Anti-condensation space heater
  • Class F temperature rise at 40C ambient
  • Right side extension box, bottom cable entry

Governing System

  • ADEM A4
  • Redundant shutdown (Overspeed protection through a duplicate speed sensing system)

Lube System

  • Gear type lube oil pump
  • Lubricating oil
  • Fumes disposal
  • Integral lube Oil cooler
  • Oil drain lines and valve
  • Oil filter, filler and dipstick
  • Prelube - required with prime, continuous, and standby

Mounting Systems

  • Rubber anti-vibration mounts - shipped loose
  • Battery disconnect switch
  • Batteries and battery rack w/cables
  • Dual 24 volt electric starting motors
  • Rails - Engine/generator

Service Instructions

  • Two PM inspections

Power Termination

  • Busbar

General

  • Paint - Caterpillar yellow with high gloss black rails & radiator
  • Right hand servicing
  • Flywheel and flywheel housing-SAE No. 00
  • SAE standard rotation
Optional Equipment

Air Inlet System

  • Single element air cleaner
  • Dual element air cleaner
  • Air inlet adapters
  • Air inlet protection

Control Panel

  • EMCP 4.4
  • EMCP 4.4 optional harness
  • Controller and MV&HV power connection locations
  • Load share module
  • Controller mounting location - LV / MV
  • Customer AC-DC connection mounting location - LV/MV
  • Load share module / auxiliary plate and auxiliary box (LV)
  • Load share governor
  • Frame boxes
  • Automatically selected ground
  • Controller voltage and current sensing groups
  • Raise lower switch
  • Speed adjust
  • Annunciator modules
  • Customer interface options
  • Generator temperature monitoring
  • Modbus monitoring of packages
  • E-Stop
  • Interconnect harness
  • Generator harness

Cooling System

  • Package mounted radiator
  • Remote radiators
  • Fuel cooler

Exhaust System

  • Front housing - Standby or mission critical
  • Front housing - Prime or continuous
  • Exhaust collectors/manifold
  • Exhaust support group
  • Mufflers
  • Weld flanges
  • Aftercooler drain

Crankcase Systems

  • Explosive relief valves
  • Crankcase ventilation system

Fuel System

  • Primary fuel filter

Generators and Attachments

  • Low voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
  • Medium voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
  • Low voltage - 1800 and 3000 Frames - 60 Hz, 3 phase, 1800 rpm, FW, PM, No of leads=6, Pitch 0.6667
  • Space heater kit
  • Thermostat for space heater
  • Conversion GP - Top cable entry
  • Generator air intake
  • Differential current transformers

Instrumentation

  • Pyrometer and thermocouples

Lube System

  • Lube oil heater
  • Drain group oil pans
  • Lubricating oil
  • Electric prelube pumps
  • Oil filters

Mounting

  • Rubber anti-vibration mounts
  • Spring type linear vibration isolators
  • IBC vibration isolators - Shipped loose

Power Connections

  • Center post busbarss (LV)
  • Side/rear mounted busbars (LV)
  • Harnesses (Breaker)
  • Cable entry options (LV)
  • Enclosures - Control packaging (LV)
  • Power connection covers (LV)
  • Neutral ground (LV)
  • 1800 Frame generators Circuit breaker
  • Masterpack breakers
  • Paralleling circuit breakers
  • 1800 Frame generator side / rear mounted busbars (MV)
  • Cable entry options (MV)
  • Neutral ground (MV)
  • Low voltage connection cable
  • Masterpack breaker connections

Special Tests / Reports

  • Generator test report
  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8 power factor
  • Standard genset TVA (Torsional Vibration Analysis) report
  • Custom generator TVA report
  • Special test charge - Engine only
  • Genset fuel consumption test
  • Standard engine test charge
  • IBC seismic Certification
  • OSCOSH1 seismic Certification

Starting / Charging System

  • 24 Volt power distribution box
  • 24 Volt electric starting motor
  • Air starting motor
  • Air pressure regulator
  • Starter location covers
  • 24 Volt battery set - Dry
  • Heavy duty battery sets with rack
  • 20 Amp Battery chargers
  • 35 Amp Battery chargers
  • 50 Amp Battery chargers
  • Charging alternators - Dry
  • Jacket water heaters
  • Jacket water heater wiring groups

General

  • Special paint colors
  • Service tools - Engine barring group
  • Barring group manual
  • Engine barring air powered
  • Control GP - air powered bar group

Similar New Power Solutions

C1.1 Generator Set
Diesel Generator Sets

C1.1 Generator Set

Standby Rating: 7.5/9.5 kVA
Prime Power Rating: 6.8/8.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C1.5 Generator Set
Diesel Generator Sets

C1.5 Generator Set

Standby Rating: 11/12/13.5/16 kVA
Prime Power Rating: 10/11/12.5/14.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C3.3 Generator Set
Diesel Generator Sets

C3.3 Generator Set

Standby Rating: 26/33/40/50 kVA
Prime Power Rating: 24/30/36/45 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage II / EU Stage IIIA

C2.2 Generator Set
Diesel Generator Sets

C2.2 Generator Set

Standby Rating: 14/16.5/18/22 kVA
Prime Power Rating: 13/15/16.5/20 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C4.4 Generator Set
Diesel Generator Sets

C4.4 Generator Set

Standby Rating: 55/65/88/90/110 kVA
Prime Power Rating: 50/60/80/82/100 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIA / EU Stage IIIA

C7.1 ACERT
Diesel Generator Sets

C7.1 ACERT

Standby Rating: 150/165/175/200/220 kVA
Prime Power Rating: 135/150/160/180/200 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIIA

3512B Diesel Generator Set
Diesel Generator Sets

3512B Diesel Generator Set

Standby Rating: 1625/1600/1500 kVA
Prime Power Rating: 1500/1360 kVA
Emissions/Fuel Strategy: Low Fuel , Low Emissions

3512 Generator Set
Diesel Generator Sets

3512 Generator Set

Standby Rating: 1400/1250 kVA
Prime Power Rating: 1275/1150 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516B Generator Set
Diesel Generator Sets

3516B Generator Set

Standby Rating: 2250 kVA
Prime Power Rating: 2000 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516 Diesel Generator Set
Diesel Generator Sets

3516 Diesel Generator Set

Standby Rating: 2000 kVA
Prime Power Rating: 1825 kVA
Emissions/Fuel Strategy: Low Fuel Consumption