C15 Generator Set

Diesel Generator Sets

Details

Standby Rating
500/550 kVA

Prime Power Rating
450/500 kVA

Emissions/Fuel Strategy
Low BSFC / EU Stage IIIA / Non-Certified Emissions

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

365 - 550 kVA Diesel Generator Set

The C15 diesel generator sets have been developed for your mission critical, standby and prime applications. Producing reliable power from 365 to 550 kVA at 50 Hz, meeting ISO 8528-5 transient response requirements and built to accept 100 % rated load in one step. The engines are certified Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 or Tier 3 Nonroad Equivalent Emission Standards), EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards Emissions / Fuel Strategy.

Benefits

Control System

  • Track Genset Health and Operation Parameters
  • Genset Utilization and Performance Tracking

Monitoring

Cat Connect option ensures your generator set is always ready to start and perform as expected

Lower Fuel Consumption

Longer run times between fuel fills; reduced operating costs

Features at a Glance

Cat Generator Set Package
        
  • Cat generator set packages have been fully prototype tested
  •     
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  •     
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
        
  • Reliable, rugged, durable design
  •     
  • Field-proven in thousands of applications worldwide
  •     
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
A-Frame Alternator
        
  • Superior motor starting capability minimizes need for oversizing alternator
  •     
  • Designed to match performance and output characteristics of Cat diesel engines
  •     
  • Robust Class H insulation
GCCP 1.3 Control Panel
        
  • User-friendly interface and navigation
  •     
  • Scalable system to meet a wide range of installation requirement
  •     
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
        
  • Designed to operate in standard ambient temperatures up to 55°C (131°F)
  •     
  • Contact your Cat Dealer for specific ambient and altitude capabilities
One Safe Source
        
  • Components used in the generator set are selected based on seamless design integration to provide the optimum performance
  •     
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  •     
  • Each generator set package is tested before leaving the Caterpillar facility
  •     
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
        
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  •     
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Certification

Certification

Specifications

Full Specifications

Generator Set Specifications

Standby Rating
500/550 kVA

Prime Power Rating
450/500 kVA

Emissions/Fuel Strategy
Low BSFC / EU Stage IIIA / Non-Certified Emissions

Voltage
208 to 600 Volts

Frequency
50 Hz

Speed
1500 rpm

Duty Cycle
Standby, Prime

Engine Specifications

Engine Model
C15 ATAAC, I-6, 4-Stroke Water-Cooled Diesel

Bore
5.4 in

Stroke
6.75 in

Displacement
927.56 in³

Compression Ratio
16.1:1

Aspiration
Air to Air Aftercooled

Fuel System
MEUI

Governor Type
Adem™A4

Generator Set Dimensions

Length - Maximum
150.8 in

Width - Maximum
58.3 in

Height - Maximum
86.3 in

Equipment

Standard Equipment

Air System

  • Turbocharger
  • Aftercooler core
  • Air cleaner - Non canister disposable paper filter

Air Inlet

  • Air cleaner

Control Panel

  • GCCP 1.3

Cooling

  • Package mounted radiator

Cooling System

  • Caterpillar extended life coolant
  • Radiator and cooling fan with guard
  • Fan drive, battery charging alternator drive
  • Coolant drain line with valve

Exhaust

  • Base, formed steel with single wall integral 8-hour fuel tank
  • Standard open set fuel tank/base supplied

Fuel

  • Primary fuel filter with integral water separator
  • Secondary fuel filters
  • Fuel priming pump

Fuel System

  • Engine fuel transfer pump
  • Primary fuel filter w/integral water separator and secondary filter
  • Fuel priming pump
  • Flexible fuel lines
  • Fuel cooler

Generator

  • Matched to the performance and output characteristics of Cat engines
  • IP23 Protection
  • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time

Power Termination

  • Busbar

Generator and Attachments

  • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
  • Optional LC Frame generator - IP23 Protection
  • Segregated low voltage (AC/DC) wiring panel
  • Integrated voltage regulator (IVR)
  • Power center, IP22

Mounting

  • Rubber vibration isolators

Governing System

  • Cat electronic governor (ADEM A4).

Lube System

  • Oil cooler
  • Oil drain valves

Mounting System

  • Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines

Starting/Charging

  • 24 Volt battery with rack and cables

General

  • Engine and alternator pre paint, Caterpillar yellow
Optional Equipment

Air Inlet System

  • Single element air cleaner
  • Dual element air cleaner

Exhaust

  • Industrial, residential, critical mufflers

Certifications

  • EU Certificate of Conformance (CE)
  • Global certification for CIS

Generator

  • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
  • Oversize and premium generators
  • Anti-condensation heater

Power Termination

  • Circuit breakers, UL listed
  • Circuit breakers, IEC compliant

Circuit breakers

  • Shunt trip for IEC circuit breaker
  • 4 Pole (IEC-100% rated) Circuit breakers - Package mounted
  • Auxiliary contacts, circuit breaker
  • 3 Pole (IEC-100% rated) Circuit breakers - Package mounted
  • 3 Pole (IEC-100% rated) Circuit breakers - Motorised
  • Power terminal strip
  • 4 Pole (IEC-100% rated) Circuit breakers - Motorised
  • Padlockable circuit breaker device

Generator and Attachments

  • Permanent magnet excitation (PMG) generator
  • LC frame CIP generator
  • Oversize LC frame generator
  • Space heaters
  • CIP A Frame generator
  • Oversize A Frame generator
  • Ingress protection
  • A Frame generator - IP21 Protection
  • LC frame generator

Control Panels

  • Fuel level sensor
  • Volt free contacts
  • Oil temperature displays
  • Local annunciator
  • GCCP 1.4
  • Local alarm horn
  • Remote annunciator module

Starting/Charging

  • Oversize batteries
  • Battery chargers
  • Jacket water heater
  • Heavy duty starting system
  • Charging alternator

Cooling System

  • Low coolant temperature alarm
  • Stone guards
  • Radiator duct flange

General

  • Narrow, wide or skid base
  • Single or dual wall integral fuel tanks
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • The following options are based on regional and product configuration:
  • Automatic transfer switches (ATS)
  • Integral & sub-base UL listed dual wall fuel tanks
  • CSA Certification
  • EEC Declaration of Conformity
  • Single or dual wall sub-base fuel tanks
  • UL 2200 package
  • Sound attenuated, weather protective or high ambient weather protective enclosure
  • EU Certificate of Conformance (CE)

Enclosures

  • High ambient sound attenuated enclosures
  • Sound attenuated enclosures

Exhaust System

  • 6 and 8 inch elbow kit
  • Manifold and turbocharger guards
  • End in/end out mufflers - 10, 25 and 35 dBA attenuation
  • Engine mounted muffler
  • 6 and 8 inch flange GP
  • Flexible exhaust fittings

Fuel System

  • Fuel transfer system controls
  • Manual fuel transfer pump
  • Optional BS799 Compliant Integral Dual wall fuel tank base

Lube System

  • Manual sump pump

Mounting System

  • Narrow skid base - replaces standard fuel tank base

Special Test / Reports

  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8 power factor

Starting / Charging System

  • 5 Amp single Battery charger
  • Jacket water heater
  • Battery disconnect switch

Similar New Power Solutions

C1.1 Generator Set
Diesel Generator Sets

C1.1 Generator Set

Standby Rating: 7.5/9.5 kVA
Prime Power Rating: 6.8/8.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C1.5 Generator Set
Diesel Generator Sets

C1.5 Generator Set

Standby Rating: 11/12/13.5/16 kVA
Prime Power Rating: 10/11/12.5/14.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C3.3 Generator Set
Diesel Generator Sets

C3.3 Generator Set

Standby Rating: 26/33/40/50 kVA
Prime Power Rating: 24/30/36/45 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage II / EU Stage IIIA

C2.2 Generator Set
Diesel Generator Sets

C2.2 Generator Set

Standby Rating: 14/16.5/18/22 kVA
Prime Power Rating: 13/15/16.5/20 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C4.4 Generator Set
Diesel Generator Sets

C4.4 Generator Set

Standby Rating: 55/65/88/90/110 kVA
Prime Power Rating: 50/60/80/82/100 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIA / EU Stage IIIA

C7.1 ACERT
Diesel Generator Sets

C7.1 ACERT

Standby Rating: 150/165/175/200/220 kVA
Prime Power Rating: 135/150/160/180/200 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIIA

3512B Diesel Generator Set
Diesel Generator Sets

3512B Diesel Generator Set

Standby Rating: 1625/1600/1500 kVA
Prime Power Rating: 1500/1360 kVA
Emissions/Fuel Strategy: Low Fuel , Low Emissions

3512 Generator Set
Diesel Generator Sets

3512 Generator Set

Standby Rating: 1400/1250 kVA
Prime Power Rating: 1275/1150 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516B Generator Set
Diesel Generator Sets

3516B Generator Set

Standby Rating: 2250 kVA
Prime Power Rating: 2000 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516 Diesel Generator Set
Diesel Generator Sets

3516 Diesel Generator Set

Standby Rating: 2000 kVA
Prime Power Rating: 1825 kVA
Emissions/Fuel Strategy: Low Fuel Consumption