3612 Generator Set (Medium Speed)

Diesel Generator Sets

Details

Maximum Rating
4000 ekW

Minimum Rating
3300 ekW

Emissions/Fuel Strategy
Low Fuel Consumption

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

3612 (60 Hz)

Producing reliable power from 3300 to 4000 ekW at 60 Hz, our 3612 diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100% rated load in one step. The generator set is certified for low fuel consumption.

Benefits

Operating hours

at Global locations

Better Fuel Economy

Demonstrated savings

Reduction in Service Time

Two inspection ports per cylinder, segmented camshafts and individual heads ease service

Features at a Glance

Cat® Diesel Engine

Cat® Diesel Engine

  • Designed and optimized for low fuel consumption
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
Alternators

Alternators

  • Superior motor starting capability minimizes need for oversizing generator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Industry leading mechanical and electrical design
  • Industry leading motor starting capabilities
  • High Efficiency
Generator Set Package

Generator Set Package

  • Fully prototype tested with certified torsional vibration analysis available
Worldwide Product Support

Worldwide Product Support

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • The Caterpillar S.O.S. program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products.
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
Cat Genset Monitoring System (GMS)

Cat Genset Monitoring System (GMS)

The Genset Monitoring System (GMS) provides protection, monitoring, and control for a single 3600 diesel generator set utilizing a digital based control panel housed in an IP55 enclosure. All critical shutdowns are a relay-based protection. Contactors are wired directly to the junction panel when an accessory module is ordered and is factory packaged. Use of the GMS eliminates the need for a separate gauge panel and annunciator panel. Accepts remote signals for starting/interlock, stopping, and emergency stop. All monitored parameters and status signals are available over MODBUS RS485 network. A default Ethernet connection is available for connection.
  • Simple user friendly interface and navigation
  • Provides protection, monitoring, and control of the generator set
  • Redundant shutdown protection
  • 5.7 inch (145 mm) color monitor to display all engine parameters and alarm annunciation
  • Annunciation of all engine shutdowns, alarms, and status points
  • Start/prelube control switch, fuel control switch and emergency stop button
  • Selection of local/remote control of engine
  • Selection of idle/rated control of engine
  • Equipped for remote communication from the panel
  • Relay outputs available: energize to run, energize to stop, air shutoff, prelube, air start and local remote
  • Optional output available for alarms and faults

Specifications

Full Specifications

Generator Set Specifications

Maximum Rating
4000 ekW

Minimum Rating
3300 ekW

Emissions/Fuel Strategy
Low Fuel Consumption

Frequency
60 Hz

Speed
720 & 900 rpm

Duty Cycle
Prime, Continuous

Engine Specifications

Engine Model
3612 V-12,4-Stroke Water-Cooled Diesel

Bore
11 in

Stroke
11.8 in

Displacement
13524 in³

Compression Ratio
13:01

Aspiration
TA

Fuel System
Direct unit injection

Governor Type
Generator Set Monitoring System (GMS)

Generator Set Dimensions

Length - Maximum
404 in

Width - Maximum
99.62 in

Height - Maximum
156.6 in

Dry Weight - Genset (maximum)
112690 lb

Equipment

Standard Equipment

Air Inlet System <!-- 3600 series only -->

  • Turbocharger, watercooled, engine oil lubricated
  • Aftercooler, fresh water, corrosion resistant coated (air side)
  • Air cleaner
  • Breather, crankcase, top-mounted
  • Air inlet shutoff

Cooling System

  • Jacket water thermostats
  • Engine coolant water drains
  • Water temperature regulator
  • Three-bundle oil cooler
  • Front mounted turbos

Exhaust System

  • Dry, gas tight, exhaust manifold
  • 457 mm (18 in) Cat bolt pattern
  • Includes adapter, flexible exhaust fitting

Fuel System

  • Simplex or duplex

Generator System

  • Custom generator per generator data sheet completed by Dealer

Governor System

  • UG Actuator

Lube System

  • Oil pressure regulating valve
  • Oil filler and dipstick
  • Service side engine mounted on cylinder block inspection covers
  • Wet oil sump. Includes engine-driven main lubrication and oil pumps, oil lines and oil pan
  • Centrifugal oil filters with single shutoff
  • Crankcase explosion relief valves

Mounting System

  • Engine and generator mounting
  • Damper, torsional vibration

Starting / Charging System

  • Vane type air starter
  • Air silencer
  • Line group for single point custom connection
  • Two motors, engine mounted at rear, on left side

General:

  • Gear driven pumps: Fuel/oil/jacket water/aftercooler/Oil cooler water
  • Paint, Caterpillar yellow
Optional Equipment

Air Inlet System

  • Boost control valve
  • Air inlet adapter
  • Soot filter
  • Vertical support bracket
  • Air cleaner louver assembly
  • Heavy duty air cleaner

Cooling System

  • Heat exchanger for single circuit
  • Heating aids
  • Cooling system aids
  • Expansion tank
  • Auxiliary water pump

Exhaust System

  • Weld flange and related hardware
  • Flexible exhaust fittings

Fuel System

  • Fuel system connections
  • Fuel priming pump
  • Duplex primary fuel strainer

Generator System

  • Busbar connections
  • Anti-condensation space heaters
  • Class F insulation
  • Winding temperature detectors
  • 3 Phase, six leads, WYE

Governor System

  • 723 Plus
  • Digital programmers
  • Electronic/actuators
  • Battery backup/power supply
  • 230 UA
  • EGB actuator

Lube System

  • Oil pan drain valve
  • Lube ANSI adapter (Emergency connection)

Mounting System

  • Spring type vibration isolators
  • Non-vertically restrained
  • Vertically restrained
  • Isolator

Starting / Charging System

  • Redundant air starters
  • Turbine type air starters
  • Pressure reducing valve
  • Compressed air flex hose

General:

  • Custom paint colors

Similar New Power Solutions

C1.1 Generator Set
Diesel Generator Sets

C1.1 Generator Set

Standby Rating: 7.5/9.5 kVA
Prime Power Rating: 6.8/8.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C1.5 Generator Set
Diesel Generator Sets

C1.5 Generator Set

Standby Rating: 11/12/13.5/16 kVA
Prime Power Rating: 10/11/12.5/14.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C3.3 Generator Set
Diesel Generator Sets

C3.3 Generator Set

Standby Rating: 26/33/40/50 kVA
Prime Power Rating: 24/30/36/45 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage II / EU Stage IIIA

C2.2 Generator Set
Diesel Generator Sets

C2.2 Generator Set

Standby Rating: 14/16.5/18/22 kVA
Prime Power Rating: 13/15/16.5/20 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C4.4 Generator Set
Diesel Generator Sets

C4.4 Generator Set

Standby Rating: 55/65/88/90/110 kVA
Prime Power Rating: 50/60/80/82/100 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIA / EU Stage IIIA

C7.1 ACERT
Diesel Generator Sets

C7.1 ACERT

Standby Rating: 150/165/175/200/220 kVA
Prime Power Rating: 135/150/160/180/200 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIIA

3512B Diesel Generator Set
Diesel Generator Sets

3512B Diesel Generator Set

Standby Rating: 1625/1600/1500 kVA
Prime Power Rating: 1500/1360 kVA
Emissions/Fuel Strategy: Low Fuel , Low Emissions

3512 Generator Set
Diesel Generator Sets

3512 Generator Set

Standby Rating: 1400/1250 kVA
Prime Power Rating: 1275/1150 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516B Generator Set
Diesel Generator Sets

3516B Generator Set

Standby Rating: 2250 kVA
Prime Power Rating: 2000 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516 Diesel Generator Set
Diesel Generator Sets

3516 Diesel Generator Set

Standby Rating: 2000 kVA
Prime Power Rating: 1825 kVA
Emissions/Fuel Strategy: Low Fuel Consumption