3516E Low Voltage Generator Set
Diesel Generator Sets
Details
Standby Rating
2750 ekW
Prime Power Rating
2500 ekW
Emissions/Fuel Strategy
Tier 2, Low NOx
Overview
2500 - 2750 ekW Diesel Generator Set
The 3516E diesel generator sets have been developed to meet your Standby and Prime applications and match your power standards. Producing reliable power from 2500 to 2750 ekW at 60 Hz, each generator set has been designed to meet ISO 8528-5 transient response requirements and to accept 100 % rated load in one step. The generator set is US EPA Stationary Emergency Use Only (Tier 2) certified.
Benefits
14% smaller footprint
Requires less space for installation
11% lower airflow
Lower cost room installation / Aids enclosure packaging
4°C improvement in ambient capability
Provides full power even on hottest days of the year
Features at a Glance
- Cat® Diesel Engine
-
- Rugged, durable design with reliable performance proven in thousands of applications worldwide
- Certified alternative fuels including Hydrotreated Vegetable Oil (HVO), Renewable Diesel (RD) and Hydrotreated Renewable Diesel (HRD) which meet EN 15940 or ASTM D975 can be used or blended with EN 590 diesel
- Cat Generator Set Package
-
- Accepts 100% block load in one step
- Meets NFPA 110 loading requirements
- Conforms to ISO 8528-5 G3 load acceptance requirements
- Reliability verified through torsional vibration, fuel consumption, oil consumption, transient performance, and endurance testing
- Alternators
-
- Superior motor starting capability minimizes need for oversizing generator
- Designed to match performance and output characteristics of Cat diesel engines
- Cooling System
-
- Cooling systems are available to operate in ambient temperatures up to 50°C (122°F)
- Tested to ensure proper generator set cooling
- Cat ECS Control Panel
-
- User-friendly interface and navigation
- Scalable system to meet a wide range of installation requirements
- Expansion modules and site specific programming for specific customer requirements
- Graphical touchscreen display
- Easily upgradeable
- Warranty
-
- 24 months/1000-hour warranty for Standby and Mission Critical ratings
- 12 months/unlimited hour warranty for Prime and Continuous ratings
- 12 months/unlimited hour warranty for Prime-DCP ratings
- Extended service protection is available to provide extended coverage options
- Worldwide Product Support
-
- Cat dealers have over 1,800 dealer branch stores operating in 200 countries
- Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements
- Financing
-
- Caterpillar offers an array of financial products to help you succeed through financial service excellence
- Options include loans, finance lease, operating lease, working capital, and revolving line of credit
- Contact your local Cat dealer for availability in your region
Specifications
Full Specifications
- Generator Set Specifications
-
Standby Rating
2750 ekWPrime Power Rating
2500 ekWEmissions/Fuel Strategy
Tier 2, Low NOxVoltage
416 to 13,800 VoltsFrequency
60 HzSpeed
1800 rpmDuty Cycle
Standby, Mission Critical, Prime-DCP, PrimeMaximum Rating
2750 ekWMinimum Rating
2500 ekW
- Engine Specifications
-
Engine Model
3516E, V-16, 4-Stroke, Water-Cooled DieselBore
6.69 inStroke
8.47 inDisplacement
4765 in³Compression Ratio
14.7:1Aspiration
ATAACFuel System
EUIGovernor Type
Adem™ A5
- Generator Set Dimensions
-
Length - Maximum
311.9 inWidth - Maximum
104.0 inHeight - Maximum
131.6 inDry Weight - Genset (maximum)
40750 lb
Equipment
- Standard Equipment
-
Air Cleaner
- Single element with service indicator
Starting
- Heavy duty electric starter(s)
Cooling
- ATAAC
- Standard Ambient Radiator
Crankcase Ventilation System
- Non filtered crankcase ventilation
Mounting System
- Rails
Controller
- Cat ECS 100
Telematics
- Ethernet
Alternator
- Form wound
- Permanent Magnet Excitation
Power Termination
- Busbar
- Optional Equipment
-
Air Cleaner
- Dual element with service indicator
Starting
- Standard batteries
- Oversized batteries
- Battery charger - 10A
- Battery charger - 20A
- Battery charger - 40A
- Battery charger - 50A
- Air starter(s)
- Jacket water heater
Cooling
- No Radiator
- High Ambient Radiator
Crankcase Ventilation System
- Filtered crankcase ventilation
- Closed filtered crankcase ventilation
Muffler
- Industrial grade (15 dB)
- Critical grade (25 dB)
- Hospital grade (35 dB)
Mounting System
- Spring vibration Isolators
- Seismic rated vibration isolators
Controller
- Cat ECS 200
- EMCP 4.4
Controller attachments
- Local annunciator module
- Remote annuciator module
- Expansion I/O module
- Remote monitoring software
Telematics
- Cellular
Extended service terms
- 2 year (prime)
- 3 year
- 5 year
- 10 year
Extended service coverage
- Silver
- Gold
- Platinum
- Platinum plus
Alternator Temperature rise (over 40°C ambient)
- 80°C
- 105°C
- 125°C/130°C
- 150°C
Alternator Output Voltage
- 416V
- 480V
- 600V
- 4160V
- 12470V
- 13200V
- 13800V
Alternator attachments
- Anti-condensation space heater
- Stator and bearing temperature monitoring and protection
Circuit breaker
- 1600A
- 2000A
- 2500A
- 3000A
- 3200A
- 4000A
- 5000A
- IEC
- UL
- 3-pole
- 4-pole
- Manually operated
- Electrically operated
Trip Unit
- LSI
- LSI-G
- LSI-P
- LSIG-P
Ancilliary Equipment
- Automatic transfer switch (ATS)
- Paralleling switchgear
- Paralleling controls
Certifications
- UL 2200
- IBC seismic certification
- OSHPD pre-approval