Maximum Rating
3500 kVA

Minimum Rating
3000 kVA

Emissions/Fuel Strategy
Tier 2 Equivalent - 1800 rpm

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

3000 - 3500 kVA Generator Set

The 3516E diesel generator sets have been developed to meet your standby and mission critical applications and match your power standards. Producing reliable power (3000 - 3500 kVA at 50 Hz), each generator set has been designed to meet ISO 8528-5 transient response requirements, accept 100 % rated load in one step and accept >50% block road recovering within G2 limits. The generator is certified Tier 2 Equivalent, US EPA Stationary Emergency / Low NOx (1/2 TA Luft).

Benefits

Accumulated Operating Hours

Proven performance in heavy-duty applications

less

Reduced amount of structural support required

Ambient

Provides full power even on hottest days of the year

Features at a Glance

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
Cat Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • EU Declaration of Conformity
  • EU Declaration of Incorporation
  • Eurasian Conformity (EAC)
One Safe Source
  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Full Specifications

Generator Set Specifications

Maximum Rating
3500 kVA

Minimum Rating
3000 kVA

Emissions/Fuel Strategy
Tier 2 Equivalent - 1800 rpm

Voltage
380 to 11000 volts

Frequency
50 Hz

Speed
1800 rpm

Duty Cycle
Standby, Mission Critical

Engine Specifications

Engine Model
3516E, V-16, 4-Stroke Water-Cooled Diesel

Bore
6.69 in

Stroke
8.46 in

Displacement
4765 in³

Compression Ratio
14.7:1

Aspiration
ATAAC

Fuel System
Electronic Unit Injection

Governor Type
Adem™5

Generator Set Dimensions

Length - Minimum
335.1 in

Length - Maximum
335.1 in

Width - Minimum
104 in

Width - Maximum
104 in

Height - Minimum
131.6 in

Height - Maximum
131.6 in

Dry Weight - Genset (minimum)
50706 lb

Dry Weight - Genset (maximum)
50,706 lb

Equipment

Standard Equipment

Air Inlet System

  • Air cleaner; single element canister type

Control System

  • Text alarm/event descriptions
  • Emergency stop pushbutton
  • IVR includes reactive droop capability
  • KVAR / PF modes
  • EMCP 4.2B
  • 3 Phase voltage sensing
  • Generator mounted - rear facing
  • Generator set packages include:
  • 24 Volt DC operation
  • Caterpillar's voltage regulator
  • RFI suppression
  • Environmental sealed front face
  • Limiter and exciter diode monitor
  • Min / max exciter
  • Controls:
  • Speed adjust
  • Alarm acknowledge
  • Auto/start/stop control
  • Engine cycle crank
  • Engine cool
  • Customizable screens
  • PLC functionality
  • Lamp test
  • Load histogram feature
  • Accessory module data link
  • Reverse power (kW) (32)
  • 6 Customer programmable digital inputs
  • 3 Phase
  • +/- 2% accuracy
  • High coolant temperature
  • 0 True RMS AC metering
  • Programmable protective relaying functions:
  • Reverse reactive power (kVAr) (32RV)
  • Communications:
  • Generator phase sequence
  • Over/under voltage (27/59)
  • Overcurrent (50/51)
  • RPM
  • Number of I/O varies on options selected
  • Overspeed
  • Serial annunciator module data link
  • Low coolant temperature
  • 4 Programmable relay outputs (Form A)
  • 1 Programmable relay outputs (Form C)
  • 3 Analog inputs
  • Over/under frequency (81 o/u)
  • Digital indication for:
  • Low coolant level
  • Failure to start (overcrank)
  • Cat connect
  • 1 Programmable digital outputs
  • DC volts
  • Operating hours
  • Coolant temperature
  • Oil pressure (psi, kPa or bar)
  • Amps (per phase & average)
  • Power factor (per phase & average)
  • Frequency (Hz)
  • Volts (L-L & L-N)
  • kW (per phase, average & percent)
  • kVA (per phase, average & percent)
  • kVAr (per phase, average & percent)
  • Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level -
  • Low oil pressure
  • kW-hr (total)
  • kVAr-hr (total)

Cooling System

  • ATAAC - 3516E package radiators shipped installed
  • Certified standard PGS provided

Exhaust System

  • Flanged faced outlet(s)
  • Dry exhaust manifold

Fuel System

  • Secondary fuel filters
  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose

General

  • Right hand servicing
  • Caterpillar yellow with high gloss black rails and radiator
  • SAE standard rotation
  • Flywheel and flywheel housing - SAE No. 00

Generator and Attachments

  • NEMA standard hole pattern
  • Medium voltage:
  • Anti-condensation space heater
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
  • Winding temperature detectors
  • High voltage:
  • Busbar connections, right side extension box, bottom cable entry
  • Form wound
  • Low voltage: Random wound - Internal excitation (IE) - Winding temperature detectors - NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby) - Busbar connections, top center mounted, top cable entry - NEMA standard hole pattern
  • 6 Lead
  • Permanent magnet excitation (PMG)
  • 3 Phase brushless, Salient pole
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)

Governing System

  • ADEM A5

Literature

  • Parts book
  • Operation & Maintenance Manual

Lubrication System

  • Integral lube oil cool
  • Oil filter, filler and dipstick
  • Oil drain lines and valve
  • Gear type lube oil pump
  • Lubricating oil
  • Fumes disposal

Mounting System

  • Rails - Engine/generator/radiator mounting
  • Anti-vibration mounts (shipped loose)
  • Rubber anti-vibration mounts - shipped loose

Starting System

  • 24 Volt electric starting motor
  • Battery disconnect switch
  • Battery and battery rack w/cables
  • 45 Amp Charging alternator
Optional Equipment

Control System

  • EMCP 4.4

Air Inlet System

  • Single element filter
  • Dual element air cleaner

Cooling System

  • Standard ambient radiators
  • Water level switch gauges
  • Optional installed ATAAC radiators
  • Optional installed radiators
  • Coolant
  • Standard ambient ATAAC radiators

Crankcase System

  • Ventilation system
  • No explosion relief valves
  • Explosion relief valves

Exhaust System

  • Y Adapters

Fuel System

  • Fuel priming pumps (Tier 4) - Manual or electric
  • Primary fuel filter

General

  • Special paint (Colors other than Caterpillar yellow or high performance paints)
  • US aid emblem

Generators and Attachments

  • Space heater
  • Differential current transformers (DCT) 8.7 kV and 15 kV classes
  • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
  • Alternator air cleaner
  • Thermostat for space heater
  • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
  • Generator conversion

Instrumentation

  • Pyrometer and thermocouples

Lubrication System

  • Oil level regulator
  • Prelube pumps
  • Lube oil in standard sump

Mounting System

  • Puck style low efficiency isolators
  • Spring type vibration isolators
  • IBC vibration isolators

Power Connections

  • Neutral ground connections
  • Center post busbars
  • Right side power connections

Special Tests / Reports

  • Generator set fuel consumption test
  • PGS Test report @ 1.0 power factor
  • Standard engine test charge
  • Canadian Standards Association certification
  • Generator test report
  • IBC Certification
  • OSHPD Certification
  • Fuel consumption test
  • Torsional vibration analysis reports
  • PGS Test report @ 0.8 power factor

Starting and Charging

  • Starter cover
  • Air pressure regulator
  • 10, 20, 35 and 50 Amp Battery chargers
  • 24 Volt battery set - Dry
  • Jacket water heaters
  • Air starting motors
  • Electric starting motors
  • Engine barring device

Extended Service Coverage

  • Platinum, Gold and Silver coverage

Similar New Power Solutions

C1.1 Generator Set
Diesel Generator Sets

C1.1 Generator Set

Standby Rating: 7.5/9.5 kVA
Prime Power Rating: 6.8/8.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C1.5 Generator Set
Diesel Generator Sets

C1.5 Generator Set

Standby Rating: 11/12/13.5/16 kVA
Prime Power Rating: 10/11/12.5/14.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C3.3 Generator Set
Diesel Generator Sets

C3.3 Generator Set

Standby Rating: 26/33/40/50 kVA
Prime Power Rating: 24/30/36/45 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage II / EU Stage IIIA

C2.2 Generator Set
Diesel Generator Sets

C2.2 Generator Set

Standby Rating: 14/16.5/18/22 kVA
Prime Power Rating: 13/15/16.5/20 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C4.4 Generator Set
Diesel Generator Sets

C4.4 Generator Set

Standby Rating: 55/65/88/90/110 kVA
Prime Power Rating: 50/60/80/82/100 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIA / EU Stage IIIA

C7.1 ACERT
Diesel Generator Sets

C7.1 ACERT

Standby Rating: 150/165/175/200/220 kVA
Prime Power Rating: 135/150/160/180/200 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIIA

3512B Diesel Generator Set
Diesel Generator Sets

3512B Diesel Generator Set

Standby Rating: 1625/1600/1500 kVA
Prime Power Rating: 1500/1360 kVA
Emissions/Fuel Strategy: Low Fuel , Low Emissions

3512 Generator Set
Diesel Generator Sets

3512 Generator Set

Standby Rating: 1400/1250 kVA
Prime Power Rating: 1275/1150 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516B Generator Set
Diesel Generator Sets

3516B Generator Set

Standby Rating: 2250 kVA
Prime Power Rating: 2000 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516 Diesel Generator Set
Diesel Generator Sets

3516 Diesel Generator Set

Standby Rating: 2000 kVA
Prime Power Rating: 1825 kVA
Emissions/Fuel Strategy: Low Fuel Consumption