3516B Generator Set

Diesel Generator Sets

Details

Standby Rating
2250 ekW

Prime Power Rating
1825 ekW

Emissions/Fuel Strategy
Low Fuel, Low Emissions

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

1640 - 2250 eKW Diesel Generator Set

Producing reliable power from 1640 to 2250 ekW at 60 Hz, our 3516B diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100% rated load in one step. Generator sets offer both low fuel consumption and low emission systems.

Benefits

Global Operating Hours

Proven performance in heavy-duty applications

Shipped

Since 1981, leading the large engine market

Lower Fuel Consumption

Demonstrated savings in operating costs

Features at a Glance

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
Cat ECS Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • UL 2200 Listed
  • CSA
  • IBC seismic certification
  • OSHPD pre-approval
One Safe Source
  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Full Specifications

Generator Set Specifications

Standby Rating
2250 ekW

Prime Power Rating
1825 ekW

Emissions/Fuel Strategy
Low Fuel, Low Emissions

Voltage
380 to 13800 Volts

Frequency
60 Hz

Speed
1800 rpm

Duty Cycle
Standby, Mission Critical, Prime, Continuous

Maximum Rating
2250 ekW

Minimum Rating
1640 ekW

Engine Specifications

Engine Model
3516B TA, V-16, 4-Stroke Water-Cooled Diesel

Bore
6.69 in

Stroke
7.48 in

Displacement
4210.64 in

Compression Ratio
14.0:1 Std 15.5:1 HD

Aspiration
TA

Fuel System
Electronic unit injection

Governor Type
Adem™3

Generator Set Dimensions

Length - Minimum
241.8 in

Length - Maximum
269.9 in

Width - Minimum
90 in

Width - Maximum
101.9 in

Height - Minimum
98.2 in

Height - Maximum
120.1 in

Dry Weight - Genset (minimum)
31270 lb

Dry Weight - Genset (maximum)
34420 lb

Equipment

Standard Equipment

Air Inlet System

  • Air cleaner; single element canister type

Cooling

  • Package mounted radiator

Exhaust

  • Exhaust flange outlet

Fuel

  • Primary fuel filter with integral water separator
  • Secondary fuel filters
  • Fuel priming pump

Generator

  • IP23 Protection
  • Matched to the performance and output characteristics of Cat engines

Power Termination

  • Busbar

Control Panel

  • Cat ECS Genset controller

General

  • Paint - Caterpillar yellow except rails and radiators gloss black

Control Panels

  • Speed adjust
  • Text alarm/event descriptions
  • Generator set packages include Caterpillar's voltage regulator
  • Auto/start/stop control
  • 24 Volt DC operation
  • Cat ECS 100
  • Generator mounted - Rear facing
  • Controls:
  • Environmental sealed front face
  • Engine cool-down timer
  • Emergency stop pushbutton
  • Limiter and exciter diode monitor
  • Engine cycle crank
  • Lamp test
  • Alarm acknowledge
  • Customizable screens
  • PLC functionality
  • Load histogram feature
  • 0 True RMS AC metering, 3-phase, +/-2% accuracy
  • Operating hours
  • Digital indication for:
  • DC volts
  • RPM
  • Coolant temperature
  • Amps (per phase & average)
  • Oil pressure (psi, kPa or bar)
  • Volts (L-L & L-N)
  • Frequency (Hz)
  • Power factor (per phase & average)
  • kW (per phase, average & percent)
  • High coolant temperature
  • Low oil pressure
  • Warning/shutdown with common LED indication of shutdowns for01/10/2018:
  • kVAr (per phase, average & percent)
  • kVA (per phase, average & percent)
  • kVAr (per phase, average & percent)
  • Emergency stop
  • Overspeed
  • Failure to start (overcrank)
  • Programmable protective relaying functions:
  • Low coolant temperature
  • Generator phase sequence
  • Low coolant level
  • 1 Programmable digital outputs
  • Gear type lube oil pump
  • Battery disconnect switch
  • Caterpillar yellow with high gloss black rails and radiator
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • Medium voltage: Form wound - Permanent magnet excitation (PMG) - Winding temperature detectors - NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby) - Busbar connections, right side extension box, bottom cable entry - NEMA standard hole pattern
  • Fumes disposal
  • Permanent magnet excitation (PMG)
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • Permanent magnet excitation (PMG)
  • NEMA standard hole pattern
  • Reverse reactive power (kVAr) (32RV)
  • Over/under voltage (27/59)
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • Permanent magnet excitation (PMG)
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
  • Permanent magnet excitation (PMG)
  • SAE standard rotation
  • Internal excitation (IE)
  • Flexible fuel lines - shipped loose
  • IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min / max exciter
  • Busbar connections, right side extension box, bottom cable entry
  • Medium voltage:
  • Communications:
  • NEMA standard hole pattern
  • Lubricating oil
  • Oil drain lines and valve
  • 3 Phase brushless, Salient pole
  • 24 Volt electric starting motor
  • 6 Customer programmable digital inputs
  • Dry exhaust manifold
  • Accessory module data link
  • ADEM A3
  • Form wound
  • ATAAC - 3516E package radiators shipped installed
  • Busbar connections, top center mounted, top cable entry
  • High voltage:
  • 4 Programmable relay outputs (Form A)
  • Anti-condensation space heater
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • Controls: Speed adjust - Auto/start/stop control - Engine cool-down timer - Engine cycle crank - Alarm acknowledge - Lamp test - Load histogram feature - PLC functionality - Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
  • NEMA standard hole pattern
  • 45 Amp Charging alternator
  • 3 Analog inputs
  • Random wound
  • Anti-vibration mounts (shipped loose)
  • Cat connect
  • Oil filter, filler and dipstick
  • Rails - Engine/generator/radiator mounting
  • Customer data link (Modbus RTU)
  • Flywheel and flywheel housing - SAE No. 00
  • English
  • Busbar connections, right side extension box, bottom cable entry
  • Serial annunciator module data link
  • Integral lube oil cool
  • Certified standard PGS provided
  • Winding temperature detectors
  • 1 Programmable relay outputs (Form C)
  • Reverse power (kW) (32)
  • Form wound - Permanent magnet excitation (PMG)
  • Right hand servicing
  • Overcurrent (50/51)
  • 6 Lead
  • Flanged faced outlet(s)
  • Low voltage:
  • Number of I/O varies on options selected
  • Battery and battery rack w/cables
  • Over/under frequency (81 o/u)
  • Fuel cooler; not included with packages without radiator
  • Busbar connections, right side extension box, bottom cable entry
  • Rubber anti-vibration mounts - shipped loose
  • NEMA standard hole pattern
Optional Equipment

Control System

  • EMCP 4.4

Air Inlet System

  • Single element filter
  • Dual element air cleaner

Exhaust

  • Exhaust mufflers

Generator

  • Permanent magnet excitation (PMG)
  • Internal excitation (IE)
  • Anti-condensation heater
  • Oversize and premium generators

Cooling System

  • Water level switch gauges
  • Standard ambient radiators
  • Coolant
  • Standard ambient ATAAC radiators
  • Optional installed ATAAC radiators
  • Air inlet protection including air shut off magnetic switch
  • Optional installed radiator

Power Termination

  • Circuit breakers, IEC compliant
  • Circuit breakers, UL listed

Control Panels

  • Generator temperature monitoring & protection
  • Remote monitoring software
  • Load share module
  • Digital I/O module

Exhaust System

  • Exhaust Offset
  • Flanges
  • Elbows
  • Y Adapters
  • Flange and exhaust expanders
  • Clean emission parets
  • Mufflers
  • Flexible fittings

Fuel System

  • Primary fuel filter

General

  • Special paint
  • US aid emblem
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • EEC Declaration of Conformity
  • Integral & sub-base fuel tanks
  • Enclosures: Sound attenuated, weather protective
  • Integral & sub-base UL listed dual wall fuel tanks
  • EU Certificate of Conformance (CE)
  • The following options are based on regional and product configuration:
  • Automatic transfer switches (ATS)
  • UL 2200 package

Mounting

  • Rubber anti-vibration mounts
  • Spring type vibration isolators
  • IBC isolators

Generators and Attachments

  • Generator conversions - IE and PM
  • 380, 440, 480, 600 Volts, 3 phase, 1800 rpm, RW, PM, No. of leads: 6, Picth: 0.6667 - 1600 Frame
  • 380, 440, 480, 600 Volts, 3 phase, 1800 rpm, RW, IE, No. of leads: 6, Picth: 0.6667 - 1600 Frame
  • 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 phase, 1800 rpm, RW, PM, No. of leads: 6, Picth: 0.6667 - 1600 and 1800 Frames
  • Alternator air cleaner
  • Space heater

Intrumentation

  • Pyrometer and thermocouples

Lube System

  • Prelube pump groups
  • Oil lever regulator
  • Lube oil

Starting/Charging

  • Battery chargers
  • Air starting motor with control and silencer
  • Heavy duty starting system
  • Oversize batteries
  • Charging alternator

Crankcase Systems

  • Crankcase protection group: No explosion relief valves; Explosion relief valves
  • Crankcase ventilation system

Mounting System

  • Spring type vibration isolators
  • IBC vibration isolators
  • Puck style low efficiency isolators

Power Connections

  • Neutral ground connections
  • Center post busbarss
  • Right, left side and rear power connections
  • Grounding groups

Special Tests / Reports

  • Standard engine test charge
  • IBC Certification
  • Special package tests: PGS Test report @ 1.0 and 0.8 power factors
  • Generator set test report
  • CSA Certification
  • Torsional vibration analysis TVA report
  • Fuel consumption test

Starting / Charging Sytem

  • Jacket water heaters

Similar New Power Solutions

C1.1 Generator Set
Diesel Generator Sets

C1.1 Generator Set

Standby Rating: 7.5/9.5 kVA
Prime Power Rating: 6.8/8.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C1.5 Generator Set
Diesel Generator Sets

C1.5 Generator Set

Standby Rating: 11/12/13.5/16 kVA
Prime Power Rating: 10/11/12.5/14.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C3.3 Generator Set
Diesel Generator Sets

C3.3 Generator Set

Standby Rating: 26/33/40/50 kVA
Prime Power Rating: 24/30/36/45 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage II / EU Stage IIIA

C2.2 Generator Set
Diesel Generator Sets

C2.2 Generator Set

Standby Rating: 14/16.5/18/22 kVA
Prime Power Rating: 13/15/16.5/20 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C4.4 Generator Set
Diesel Generator Sets

C4.4 Generator Set

Standby Rating: 55/65/88/90/110 kVA
Prime Power Rating: 50/60/80/82/100 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIA / EU Stage IIIA

C7.1 ACERT
Diesel Generator Sets

C7.1 ACERT

Standby Rating: 150/165/175/200/220 kVA
Prime Power Rating: 135/150/160/180/200 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIIA

3512B Diesel Generator Set
Diesel Generator Sets

3512B Diesel Generator Set

Standby Rating: 1625/1600/1500 kVA
Prime Power Rating: 1500/1360 kVA
Emissions/Fuel Strategy: Low Fuel , Low Emissions

3512 Generator Set
Diesel Generator Sets

3512 Generator Set

Standby Rating: 1400/1250 kVA
Prime Power Rating: 1275/1150 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516B Generator Set
Diesel Generator Sets

3516B Generator Set

Standby Rating: 2250 kVA
Prime Power Rating: 2000 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516 Diesel Generator Set
Diesel Generator Sets

3516 Diesel Generator Set

Standby Rating: 2000 kVA
Prime Power Rating: 1825 kVA
Emissions/Fuel Strategy: Low Fuel Consumption