Standby Rating
1750 ekW

Prime Power Rating
1600 ekW

Emissions/Fuel Strategy
U.S. EPA Cert., Tier 2

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

1750 eKW Diesel Generator Set

Producing reliable power of 1750 ekW at 60 Hz, our 3512C diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100% rated load in one step. Generator sets are U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

Benefits

Global Operating Hours

Proven performance in heavy-duty applications

Shipped

Since 1981, leading the large engine market

Ambient

Provides full power even on hottest days of the year

Features at a Glance

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
Cat ECS Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
        
  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  •     
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • UL2200
  • CSA Certified
  • IBC seismic certification
  • OSHPD pre-approval
One Safe Source
  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Full Specifications

Generator Set Specifications

Standby Rating
1750 ekW

Prime Power Rating
1600 ekW

Emissions/Fuel Strategy
U.S. EPA Cert., Tier 2

Voltage
380 to 13800 Volts

Frequency
60 Hz

Speed
1800 rpm

Duty Cycle
Standby, Mission Critical

Maximum Rating
1750 ekW

Minimum Rating
1600 ekW

Engine Specifications

Engine Model
3512C ATAAC, V-12, 4-Stroke Water-Cooled Diesel

Bore
6.69 in

Stroke
8.46 in

Displacement
3574 in³

Compression Ratio
14.7:1

Aspiration
TA

Fuel System
Electronic unit injection

Governor Type
ADEM™ A3

Generator Set Dimensions

Length - Minimum
231.3 in

Length - Maximum
231.3 in

Width - Minimum
89.7 in

Width - Maximum
89.7 in

Height - Minimum
104.4 in

Height - Maximum
104.4 in

Dry Weight - Genset (minimum)
31837 lb

Dry Weight - Genset (maximum)
31837 lb

Equipment

Standard Equipment

Air Inlet System

  • Air cleaner; single element canister type with service indicator

Cooling

  • Package mounted radiator

Exhaust

  • Exhaust flange outlet

Fuel

  • Primary fuel filter with integral water separator
  • Fuel priming pump
  • Secondary fuel filters

Generator

  • Matched to the performance and output characteristics of Cat engines
  • IP23 Protection

Power Termination

  • Busbar

Control Panel

  • Cat ECS Genset controller

Control System

  • Generator set packages include Caterpillar's voltage regulator (IVR). IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min/max exciter. Limiter and exciter diode monitor
  • Emergency stop pushbutton
  • Oil pressure (psi, kPa or bar)
  • 1 Programmable digital outputs
  • Accessory module data link
  • 4 Programmable relay outputs (Form A)
  • kVAr-hr (total)
  • Reverse power (kW) (32)
  • kVAr (per phase, average & percent)
  • Amps (per phase & average)
  • Over/under frequency (81 o/u)
  • Cat ECS 100
  • PLC functionality
  • 1 Programmable relay outputs (Form C)
  • Programmable protective relaying functions:
  • RPM
  • Frequency (Hz)
  • Low coolant level
  • Number of I/O varies on options selected
  • Lamp test
  • kVA (per phase, average & percent)
  • Emergency stop
  • kW (per phase, average & percent)
  • Engine cool-down timer
  • Speed adjust
  • Generator phase sequence
  • Over/under voltage (27/59)
  • Warning/shutdown with common LED indication of shutdowns for:
  • Customer data link (Modbus RTU)
  • Volts (L-L & L-N)
  • High coolant temperature
  • Engine cycle crank
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Low coolant temperature
  • Low oil pressure
  • Cat connect
  • Digital indication for:
  • Communications
  • Environmental sealed front face
  • Reverse reactive power (kVAr) (32RV)
  • 24 Volt DC operation
  • Power factor (per phase & average)
  • Overspeed
  • Auto/start/stop control
  • Load histogram feature
  • Controls:
  • Failure to start (overcrank)
  • Customizable screens
  • kW-hr (total)
  • Text alarm/event descriptions
  • Alarm acknowledge
  • Overcurrent (50/51)
  • Generator mounted - rear facing
  • Coolant temperature
  • DC volts

Governing System

  • ADEM III

Cooling System

  • SCAC
  • Fan and belt guards
  • Caterpillar extended life coolant (Not included with packages without radiator, installed SF44CTS
  • Coolant level sensors (Not included with packages without radiator)
  • Radiator fan and fan drive
  • Coolant drain line with valve

Exhaust System

  • Flanged faced outlet(s)
  • Dry exhaust manifold

Fuel System

  • Secondary fuel filters
  • Fuel priming pump
  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines - shipped loose

Generators and Attachments

  • Random wound
  • Permanent magnet excitation (PMG)
  • High voltage
  • Six lead
  • NEMA standard hole pattern
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
  • NEMA standard hole pattern
  • Winding temperature detectors
  • NEMA standard hole pattern
  • Internal excitation (IE)
  • Form wound
  • 3 Phase brushless, Salient pole
  • Busbar connections, right side extension box, bottom cable entry
  • Low voltage:
  • Busbar connections, top center mounted, top cable entry
  • Medium voltage:

Literature

  • Parts book

Lube System

  • Oil drain lines and valve
  • Lubricating oil
  • Oil filter, filler and dipstick
  • Fumes disposal
  • Gear type lube oil pump
  • Integral lube Oil cooler

Mounting System

  • Rubber anti-vibration mounts - shipped loose

Starting / Charging System

  • Battery and battery rack w/cables
  • 45 Amp Charging alternator
  • 24 Volt electric starting motor
  • Battery disconnect switch

General

  • Paint - Caterpillar yellow except rails and radiators gloss black
  • SAE standard rotation
  • Right hand servicing
  • Flywheel and Flywheel housing-SAE No. 00
  • Paint - Caterpillar yellow with high gloss black rails & radiator
Optional Equipment

Control Panels

  • Digital I/O module
  • EMCP 4.4
  • Load share module
  • Remote monitoring software
  • Generator temperature monitoring & protection

Exhaust

  • Exhaust mufflers

Air Inlet System

  • Heavy duty air cleaner
  • Single element filter

Generator

  • Permanent magnet excitation (PMG)
  • Anti-condensation heater
  • Internal excitation (IE)
  • Oversize and premium generators

Power Termination

  • Circuit breakers, IEC compliant
  • Circuit breakers, UL listed

Cooling System

  • Standard installed radiators
  • Standard installed ATAAC radiators
  • Optional installed ATAAC radiators
  • Water level switch gauges
  • Coolant
  • Optional installed radiators

Exhaust System

  • Flanges
  • Flange and exhaust expanders
  • Flexible fittings
  • Elbows
  • Y Adapters
  • Mufflers

Fuel System

  • Primary fuel filter

Starting/Charging

  • Heavy duty starting system
  • Charging alternator
  • Battery chargers
  • Oversize batteries
  • Air starting motor with control and silencer
  • Jacket water heater

Generators and Attachments

  • 1400, 1600, 2700 Frames
  • Space heater
  • Generator conversion from IE to PM
  • Differential current transformers (DCT) 15 kV class
  • RW, IE, 6 Leads, Pitch 0.6667
  • Generator air cleaner
  • Low voltage: 380,440 / 480 Volts, 3 Phase, 1800 rpm
  • Differential current transformers (DCT) 8.7 kV class

Instrumentation

  • Wiring GP W/O cyl sensors
  • Pyrometer and thermocouples

Lube System

  • Oil drains
  • Lubrication oil in standard sump
  • Oil level regulator
  • Prelube pumps

General

  • US aid emblem
  • The following options are based on regional and product configuration:
  • Automatic transfer switches (ATS)
  • EU Certificate of Conformance (CE)
  • CSA Certification
  • Integral & sub-base UL listed dual wall fuel tanks
  • EEC Declaration of Conformity
  • UL 2200 package
  • Integral & sub-base fuel tanks
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • Enclosures: Sound attenuated, weather protective

Crankcase Protection

  • Crankcase ventilation system
  • No explosion relief valves
  • No crankcase explosion relief valves
  • Explosion relief valves

Mounting System

  • Spring type vibration isolators
  • IBC vibration isolators
  • Puck style low efficiency isolators

Mounting

  • IBC isolators
  • Rubber anti-vibration mounts
  • Spring type vibration isolators

Power Connections

  • 1600 ,2000, 2500, 3000, 4000 Amp, 3 Pole, UL-100% rated Circuit breakers
  • Grounding groups
  • Neutral ground connections
  • Right side power connections
  • Rear power connections
  • Left side power connections
  • Six lead, six terminal option
  • 2000, 2500, 3200 Amp, 3 Pole, IEC rated Circuit breakers
  • Center post busbars
  • 2000, 2500 Amp, 4 Pole, IEC rated Circuit breakers
  • Cable entry - right side

Special Tests / Reports

  • Fuel consumption test
  • Generator test report
  • IBC seismic Certification
  • PGS Test report @ 1.0 power factor
  • Standard engine test charge
  • CSA Certification
  • Generator fuel consumption test
  • Torsional vibration analysis
  • PGS Test report @ 0.8 power factor

Starting / Charging System

  • 24 Volt battery set - Dry
  • Air pressure regulator
  • 10 Amp Battery charger
  • Air starting motor
  • 35 Amp Battery charger
  • Jacket water heaters
  • Starter cover
  • Engine barring device
  • Batteries, racks and cables:
  • Electric starting motors

Similar New Power Solutions

C1.1 Generator Set
Diesel Generator Sets

C1.1 Generator Set

Standby Rating: 7.5/9.5 kVA
Prime Power Rating: 6.8/8.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C1.5 Generator Set
Diesel Generator Sets

C1.5 Generator Set

Standby Rating: 11/12/13.5/16 kVA
Prime Power Rating: 10/11/12.5/14.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C3.3 Generator Set
Diesel Generator Sets

C3.3 Generator Set

Standby Rating: 26/33/40/50 kVA
Prime Power Rating: 24/30/36/45 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage II / EU Stage IIIA

C2.2 Generator Set
Diesel Generator Sets

C2.2 Generator Set

Standby Rating: 14/16.5/18/22 kVA
Prime Power Rating: 13/15/16.5/20 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C4.4 Generator Set
Diesel Generator Sets

C4.4 Generator Set

Standby Rating: 55/65/88/90/110 kVA
Prime Power Rating: 50/60/80/82/100 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIA / EU Stage IIIA

C7.1 ACERT
Diesel Generator Sets

C7.1 ACERT

Standby Rating: 150/165/175/200/220 kVA
Prime Power Rating: 135/150/160/180/200 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIIA

3512B Diesel Generator Set
Diesel Generator Sets

3512B Diesel Generator Set

Standby Rating: 1625/1600/1500 kVA
Prime Power Rating: 1500/1360 kVA
Emissions/Fuel Strategy: Low Fuel , Low Emissions

3512 Generator Set
Diesel Generator Sets

3512 Generator Set

Standby Rating: 1400/1250 kVA
Prime Power Rating: 1275/1150 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516B Generator Set
Diesel Generator Sets

3516B Generator Set

Standby Rating: 2250 kVA
Prime Power Rating: 2000 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516 Diesel Generator Set
Diesel Generator Sets

3516 Diesel Generator Set

Standby Rating: 2000 kVA
Prime Power Rating: 1825 kVA
Emissions/Fuel Strategy: Low Fuel Consumption