3512C Generator Set

Diesel Generator Sets

Details

Standby Rating
1500 ekW

Prime Power Rating
1360 ekW

Emissions/Fuel Strategy
U.S. EPA Certified

Contact

Foley Equipment Sales

+1 (316) 943-4211

Request a Quote

Overview

1230 - 1500 ekW Diesel Generator Set

Producing reliable power from 1230 to 1500 ekW at 60 Hz, our 3512C diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100% rated load in one step. Generator sets are U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

Benefits

Global Operating hours

Proven performance in heavy-duty applications

Shipped

Since 1981, leading the large engine market

Lower Than Other Brands

Provides great block load capability and durability

Features at a Glance

Cat Generator Set Package
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements
Cat Diesel Engine
  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight
SR5 Alternator
  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation
Cat ECS Control Panel
  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements
Cooling System
  • Designed to operate in standard ambient temperatures up to 50�C (122�F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities
Certifications
  • UL 2200 Listed
  • CSA
  • IBC seismic certification
  • OSHPD pre-approval
One Safe Source
  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system
Worldwide Product Support
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Specifications

Full Specifications

Generator Set Specifications

Standby Rating
1500 ekW

Prime Power Rating
1360 ekW

Emissions/Fuel Strategy
U.S. EPA Certified

Voltage
380 to 13800 Volts

Frequency
60 Hz

Speed
1800 rpm

Duty Cycle
Standby, Mission Critical, Prime, Continuous

Maximum Rating
1500 ekW

Minimum Rating
1230 ekW

Engine Specifications

Engine Model
3512C ATAAC, V-12, 4-Stroke Water-Cooled Diesel

Bore
6.69 in

Stroke
7.48 in

Displacement
3161.03 in³

Compression Ratio
14.7:1

Aspiration
TA

Fuel System
Electronic unit injection

Governor Type
ADEM™ A3

Generator Set Dimensions

Length - Minimum
222.2 in

Length - Maximum
221.2 in

Width - Minimum
89.7 in

Width - Maximum
89.7 in

Height - Minimum
104.4 in

Height - Maximum
104.4 in

Dry Weight - Genset (minimum)
28971 lb

Dry Weight - Genset (maximum)
28971 lb

Equipment

Standard Equipment

Air Inlet System

  • Air cleaner; single element canister type with service indicator

Air Inlet

  • Air cleaner

Cooling

  • Package mounted radiator

Exhaust

  • Exhaust flange outlet

Fuel

  • Secondary fuel filters
  • Primary fuel filter with integral water separator
  • Fuel priming pump

Generator

  • Matched to the performance and output characteristics of Cat engines
  • IP23 Protection

Power Termination

  • Busbar

Control Panel

  • Cat ECS Genset controller

Control System

  • Alarm acknowledge
  • Over/under frequency (81 o/u)
  • Reverse power (kW) (32)
  • Coolant temperature
  • kVAr (per phase, average & percent)
  • Overcurrent (50 / 51)
  • High coolant temperature
  • Environmental sealed front face
  • Reverse reactive power (kVAr) (32RV)
  • kVA (per phase, average & percent)
  • Volts (L-L & L-N)
  • Generator set packages include Caterpillar's voltage regulator (IVR). IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min/max exciter. Limiter and exciter diode monitor
  • kW-hr (total)
  • kW (per phase, average & percent)
  • Low oil pressure
  • Cat ECS 100
  • Digital indication for:
  • Engine cool-down timer
  • Generator mounted - rear facing
  • DC volts
  • 1 programmable relay outputs (Form C)
  • Overspeed
  • kVAr-hr (total)
  • 1 programmable digital outputs
  • Communications
  • Power factor (per phase & average)
  • Oil pressure (psi, kPa or bar)
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Cat connect
  • Customizable screens
  • Low coolant temperature
  • Over/under voltage (27 / 59)
  • 4 programmable relay outputs (Form A)
  • Accessory module data link
  • Warning/shutdown with common LED indication of shutdowns for:
  • Failure to start (overcrank)
  • Amps (per phase & average)
  • Auto/start/stop control
  • Controls:
  • Engine cycle crank
  • Customer data link (Modbus RTU)
  • Programmable protective relaying functions:
  • Text alarm/event descriptions
  • Emergency stop
  • Speed adjust
  • Number of I/O varies on options selected
  • Lamp test
  • RPM
  • 24 Volt DC operation
  • Emergency stop pushbutton
  • Low coolant level
  • Frequency (Hz)
  • Generator phase sequence
  • Load histogram feature
  • PLC functionality

Cooling System

  • Coolant level sensors (Not included with packages without radiator)
  • SCAC
  • Radiator fan and fan drive
  • Coolant drain line with valve
  • Fan and belt guards
  • Caterpillar extended life coolant (Not included with packages without radiator, installed SF44CTS
    �

Exhaust System

  • Flanged faced outlet(s)
  • Dry exhaust manifold

Fuel System

  • Fuel cooler; not included with packages without radiator
  • Secondary fuel filters
  • Flexible fuel lines - shipped loose
  • Fuel priming pump

Generators and Attachments

  • Medium voltage:
  • Internal excitation (IE)
  • High voltage
  • Permanent magnet excitation (PMG)
  • Winding temperature detectors
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
  • Busbar connections, right side extension box, bottom cable entry
  • Busbar connections, top center mounted, top cable entry
  • Low voltage:
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • NEMA standard hole pattern
  • 3 phase brushless, Salient pole
  • NEMA standard hole pattern
  • 6 Leads
    �
  • Random wound
  • NEMA standard hole pattern
  • Form wound

Governing System

  • ADEM III

Literature

  • Parts book

Lube System

  • Gear type lube oil pump
  • Oil filter, filler and dipstick
  • Fumes disposal
  • Lubricating oil
  • Oil drain lines and valve
  • Integral lube Oil cooler

Mounting System

  • Rubber anti-vibration mounts - shipped loose

Starting / Charging System

  • 45 Amp Charging alternator
  • Battery and battery rack w/cables
  • Battery disconnect switch
  • 24 Volt electric starting motor

General

  • Flywheel and Flywheel housing-SAE No. 00
  • SAE standard rotation
  • Right hand servicing
  • Paint - Caterpillar yellow with high gloss black rails & radiator
Optional Equipment

Control Panels

  • EMCP 4.4

Exhaust

  • Exhaust mufflers

Air Inlet System

  • Heavy duty air cleaner
  • Single element filter

Generator

  • Permanent magnet excitation (PMG)
  • Oversize and premium generators
  • Internal excitation (IE)
  • Anti-condensation heater

Cooling System

  • Coolant
  • Standard installed ATAAC radiators
  • Optional installed ATAAC radiators
  • Optional installed radiators
  • Water level switch gauges
  • Standard installed radiators

Power Termination

  • Circuit breakers, IEC compliant
  • Circuit breakers, UL listed

Exhaust System

  • Flanges
  • Flange and exhaust expanders
  • Y Adapters
  • Flexible fittings
  • Elbows
  • Mufflers

Fuel System

  • Primary fuel filter

General

  • US aid emblem

Mounting

  • IBC isolators
  • Rubber anti-vibration mounts
  • Spring type vibration isolators

Generators and Attachments

  • Differential current transformers (DCT) 15 kV class
  • RW, IE, 6 Leads, Pitch 0.6667
  • Differential current transformers (DCT) 8.7 kV class
  • 1400, 1600, 2700 Frames
  • Space heater
  • Generator air cleaner
  • Generator conversion from IE to PM
  • Low voltage: 380,440 / 480 Volts, 3 Phase, 1800 rpm

Starting/Charging

  • Jacket water heater
  • Air starting motor with control and silencer
  • Battery chargers
  • Charging alternator
  • Heavy duty starting system
  • Oversize batteries

Instrumentation

  • Wiring GP W/O cyl sensors
  • Pyrometer and thermocouples

Lube System

  • Prelube pumps
  • Oil level regulator
  • Oil drains
  • Lubrication oil in standard sump

Crankcase Protection

  • No explosion relief valves
  • No crankcase explosion relief valves
  • Explosion relief valves
  • Crankcase ventilation system

Mounting System

  • Puck style low efficiency isolators
  • IBC vibration isolators
  • Spring type vibration isolators

Power Connections

  • Cable entry - right side
  • Center post buss bar
  • Rear power connections
  • Right side power connections
  • 2000, 2500, 3200 Amp, 3 Pole, IEC rated Circuit breakers
  • 1600 ,2000, 2500, 3000, 4000 Amp, 3 Pole, UL-100% rated Circuit breakers
  • Left side power connections
  • Six lead, six terminal option
  • 2000, 2500 Amp, 4 Pole, IEC rated Circuit breakers
  • Neutral ground connections
  • Grounding groups

Special Tests / Reports

  • Standard engine test charge
  • PGS Test report @ 1.0 power factor
  • CSA Certification
  • IBC seismic Certification
  • Fuel consumption test
  • Torsional vibration analysis
  • Generator test report
  • Generator fuel consumption test
  • PGS Test report @ 0.8 power factor

Starting / Charging System

  • 10 Amp Battery charger
  • 24 Volt battery set - Dry
  • Engine barring device
  • 35 Amp Battery charger
  • Air starting motor
  • Air pressure regulator
  • Batteries, racks and cables:
  • Jacket water heaters
  • Electric starting motors
  • Starter cover

Similar New Power Solutions

C1.1 Generator Set
Diesel Generator Sets

C1.1 Generator Set

Standby Rating: 7.5/9.5 kVA
Prime Power Rating: 6.8/8.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C1.5 Generator Set
Diesel Generator Sets

C1.5 Generator Set

Standby Rating: 11/12/13.5/16 kVA
Prime Power Rating: 10/11/12.5/14.5 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C3.3 Generator Set
Diesel Generator Sets

C3.3 Generator Set

Standby Rating: 26/33/40/50 kVA
Prime Power Rating: 24/30/36/45 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage II / EU Stage IIIA

C2.2 Generator Set
Diesel Generator Sets

C2.2 Generator Set

Standby Rating: 14/16.5/18/22 kVA
Prime Power Rating: 13/15/16.5/20 kVA
Emissions/Fuel Strategy: EU Stage IIIA

C4.4 Generator Set
Diesel Generator Sets

C4.4 Generator Set

Standby Rating: 55/65/88/90/110 kVA
Prime Power Rating: 50/60/80/82/100 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIA / EU Stage IIIA

C7.1 ACERT
Diesel Generator Sets

C7.1 ACERT

Standby Rating: 150/165/175/200/220 kVA
Prime Power Rating: 135/150/160/180/200 kVA
Emissions/Fuel Strategy: Low BSFC / EU Stage IIIA

3512B Diesel Generator Set
Diesel Generator Sets

3512B Diesel Generator Set

Standby Rating: 1625/1600/1500 kVA
Prime Power Rating: 1500/1360 kVA
Emissions/Fuel Strategy: Low Fuel , Low Emissions

3512 Generator Set
Diesel Generator Sets

3512 Generator Set

Standby Rating: 1400/1250 kVA
Prime Power Rating: 1275/1150 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516B Generator Set
Diesel Generator Sets

3516B Generator Set

Standby Rating: 2250 kVA
Prime Power Rating: 2000 kVA
Emissions/Fuel Strategy: Low fuel, Low Emissions

3516 Diesel Generator Set
Diesel Generator Sets

3516 Diesel Generator Set

Standby Rating: 2000 kVA
Prime Power Rating: 1825 kVA
Emissions/Fuel Strategy: Low Fuel Consumption