CN5086 Electric Motor
Gas Compression Electric Motors
Details
Voltage/Frequency
4000V ± 10%/60 Hz
Type of EX-Protection
Class 1 Division 2, Group A,B,C,D T3 (NEC or CEC)
Electric Motor Type
Squirrel Cage Induction Motor
Overview
Get power built for your most demanding gas compression applications. Every Cat® electric motor is tested at each stage of production to make sure it performs reliably under load and according to your process requirements. High operating efficiency and low operating costs come with low noise levels and no emissions. Cat electric motors for gas compression are backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty.
Specifications
Full Specifications
- Electric Motor Specifications
-
Voltage/Frequency
4000V ± 10%/60 HzType of EX-Protection
Class 1 Division 2, Group A,B,C,D T3 (NEC or CEC)Electric Motor Type
Squirrel Cage Induction MotorMounting Designation
F1 or F2Number of Poles
8Full Load Speed
894.0 r/minConnection of Stator Winding
StarRated Torque
29366 lb/ftStandards
NEMA MG1Maximum Altitude - Before Derate
3000 ftService Factor
1.15 SFNo Load Current
200 AmpsMaximum Ambient Temperature
104 °FTemperature Rise
Class B at rated loadShaft
8.5 inInsulation
Class FEnclosure Type/Method of Cooling
WP-IIDuty
ContinuousLocked Rotor Amps
520% Code EFull Load Current
658 AmpsLocked Rotor Torque
60%Breakdown Torque
190%
Equipment
- Standard Equipment
-
Bearings
- Self-lubricated sleeve bearings
- Insulated non-drive end bearings to reduce bearing currents
- Bearing RTDs for temperature monitoring
Rotors
- Designed for minimal vibration
- Dynamic balancing at full operational speed
- Fabricated copper squirrel cages
- Oversized, forged, keyless shaft
- AISI 4140/DIN42CrMo4 shaft
Stators
- Radial air ducts ensure uniform and efficient cooling
- Vacuum pressure impregnated with specially formulated epoxy resin
- 2X RTDS per Phase
- Space heater
- Welded and machined stator core retains its rigidity throughout motor life to ensure a sealed and homogeneous insulation system that results in high dielectric strength, excellent heat transfer and the elimination of hazardous internal partial discharges